Your browser doesn't support javascript.
loading
Assessment of diagnostic potential of office mini-hysteroscopy in gynecologial diagnosis
Bulletin of Alexandria Faculty of Medicine. 2001; 37 (4): 457-461
em Inglês | IMEMR | ID: emr-172841
ABSTRACT
To evaluate feasibility of diagnostic office mini-hysteroscopy for gynecological diagnosis. One hundred and fifty patients with different gynecologic problems were examined by transvaginal sonography [TVS]. An informed consent was obtained for examination by office mini-hysteroscopy; a Wolf rigid 2.7 mm hysteroscope was utilized. Endometrial biopsy was taken with vacuum aspiration curette in cases of abnormal uterine bleeding. The study revealed that TVS had sensitivity of 47.3% and specificity 67.2% as compared to 98.7% and 100% respectively for office hysteroscopy in the diagnosis of the whole study cases. In abnormal uterine bleeding, the diagnostic accuracy of office hysteroscopy showed 97% sensitivity and 100% specificity. Mini-hysteroscopic diagnosis of intra-uterine lesions was 100% sensitive and 100% specific. Office mini-hysteroscopy is an accurate, reliable and fast method for evaluation of intra-uterine pathology with minimal morbidity and high patient acceptance. It should be considered an indispensable modality for routine investigation in gynecologic diagnosis
Assuntos
Buscar no Google
Índice: IMEMR (Mediterrâneo Oriental) Assunto principal: Histeroscopia / Ultrassonografia / Sensibilidade e Especificidade Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Bull. Alex. Fac. Med. Ano de publicação: 2001

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: IMEMR (Mediterrâneo Oriental) Assunto principal: Histeroscopia / Ultrassonografia / Sensibilidade e Especificidade Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Bull. Alex. Fac. Med. Ano de publicação: 2001