Single photon emission computed tomography of technetium 99m tetrofosmin myocradial perfusion imaging in patients with sytemic lupus erythematosus: a preliminary report
Medical Journal of Cairo University [The]. 2006; 74 (2): 291-294
em Inglês
| IMEMR
| ID: emr-79196
ABSTRACT
This study was to evaluate the utility of single-photon emission computed tomography [SPECT] of Technetium 99m tetrofosmin [Tc-99m TF] myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus [SLE] Three groups of subjects-group 1 25 SLE female patients with non-specific cardiac symptoms and signs, group 2 25 female SLE patients without any cardiac symptoms and signs, and group 3 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardia] perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TP myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs
Buscar no Google
Índice:
IMEMR (Mediterrâneo Oriental)
Assunto principal:
Tomografia Computadorizada de Emissão de Fóton Único
/
Seguimentos
/
Infarto do Miocárdio
Tipo de estudo:
Ensaio Clínico Controlado
Limite:
Feminino
/
Humanos
Idioma:
Inglês
Revista:
Med. J. Cairo Univ.
Ano de publicação:
2006
Similares
MEDLINE
...
LILACS
LIS