Intralenticular foreign body with a clear lens
JCPSP-Journal of the College of Physicians and Surgeons Pakistan. 2010; 20 (3): 214-215
em Inglês | IMEMR | ID: emr-93233
ABSTRACT
Intraocular foreign bodies [IOFBs] are not uncommon in patients of penetrating ocular trauma but intralenticular foreign bodies are rarely seen. Penetrating ocular injuries are observed more commonly in young men. Intralenticular foreign bodies cause visually significant cataract in almost all cases. We report here a case of a young soldier with intralenticular foreign body of about 1.5 mm in size sparing the visual axis and only causing focal cataractous changes. The foreign body remained innocuous for about 3 months of follow-up not causing any progressive cataract, glaucoma or uveitis. The foreign body was removed, lens aspiration was done and posterior chamber intraocular lens was implanted, as patient could not be followed on long-term basis. The vision was restored to normally within 2 months