Your browser doesn't support javascript.
loading
Comparative accuracy of glucose monitors
Arch. med. res ; 29(4): 325-9, oct.-dic. 1998. tab, ilus
Artigo em Inglês | LILACS | ID: lil-232653
ABSTRACT
Background. Self-monitoring of blood glucose levels has become an important instrument for the management of patients with diabetes mellitus. Both patients and physicians expect that monitors will provide reliable results. Numerous environmental, physiologic, and operational factors can affects system performance, yielding results that are inaccurate or unpredictable. Methods. This study examined the effect of one factor -high altitude- on the performance of seven blood glucose monitoring systems. The following monitors were compared. two One Touch II; two One Touch Basic; two Reflolux II (Accu-Chec in the USA); two Glucometer 3; one Glucometer 2, and one Accutrend Alpha. Double blood glucose level values were compared with a cotrolled reference laboratory test values, which was unknown to the investigator until the end of the study because the study was double blind. Blood glucose values were obtained using each of the monitors in 200 patients; 150 with diabetes mellitus, and 50 healthy subjects. Results. The One Touch monitors were the only monitors that reported adjusted straight lines (Y0a+bX) that were very similar for all three techniques. In addition, these adjusted straight lines are those closest to the ideal line, Y=X. These same monitors were the only ones that did not reject the null hypothesis Ho a=0. The relative deviation index at the 20 percent level was less than 3.5 percent for the One Touch II and One Touch Basic monitors; for the rest of the monitors the index was over 14 percent. The clinically accepted EGA region was similar for all study monitors. Conclusions. In conclusion, the One Touch II and One touch Basic Monitors showed greater accuracy in comparison to the other devices. The evaluation of the clinically acceptable region shows practical reliability for all of the monitor used
Assuntos
Buscar no Google
Índice: LILACS (Américas) Assunto principal: Automonitorização da Glicemia / Reprodutibilidade dos Testes / Diabetes Mellitus / Equipamentos e Provisões Tipo de estudo: Ensaio Clínico Controlado Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Arch. med. res Assunto da revista: Medicina Ano de publicação: 1998 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Automonitorização da Glicemia / Reprodutibilidade dos Testes / Diabetes Mellitus / Equipamentos e Provisões Tipo de estudo: Ensaio Clínico Controlado Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Arch. med. res Assunto da revista: Medicina Ano de publicação: 1998 Tipo de documento: Artigo