Your browser doesn't support javascript.
loading
Internal carotid artery stenosis: comparison of duplex scan and magnetic resonance angiography with digital subtraction angiography
Py, Marco Oliveira; André, Charles; Azevedo, Feliciano Silva de; Domingues, Romeu Côrtes; Salomäo, Rodrigo Ferraz.
  • Py, Marco Oliveira; Universidade Federal do Rio de Janeiro. Hospital Universitário Clementino Fraga Filho. Department of Internal Medicine. Neurological Service. Rio de Janeiro. BR
  • André, Charles; Universidade Federal do Rio de Janeiro. Hospital Universitário Clementino Fraga Filho. Department of Internal Medicine. Neurological Service. Rio de Janeiro. BR
  • Azevedo, Feliciano Silva de; Universidade Federal do Rio de Janeiro. Hospital Universitário Clementino Fraga Filho. Department of Radiology. Rio de Janeiro. BR
  • Domingues, Romeu Côrtes; Instituto de Ressonância Magnética. BR
  • Salomäo, Rodrigo Ferraz; PREVILAB. BR
Arq. neuropsiquiatr ; 59(3B): 665-671, Sept. 2001. graf, tab
Artigo em Inglês | LILACS | ID: lil-295827
ABSTRACT

OBJECTIVE:

We compare duplex scan (DS) and magnetic resonance angiography (MRA) with digital angiography (DGA) in respect to accuracy in measuring internal carotid artery (IC) stenosis in symptomatic patients.

METHOD:

Ten symptomatic patients with IC stenosis greater than 70 percent previously diagnosed by DS were submitted to another DS and to both MRA and DGA. Both ICs from each patient (total 20 ICs) were evaluated by physicians blinded for the results of other tests. DS and MRA were compared with DGA, using the intraclass correlation coeficient (r) and its 95 percent confidence interval (95 percent ci). For each diagnostic test, the study group (20 Ics) was also divided in surgical patients (IC stenosis between 70 and 99 percent) and non surgical patients, using kappa concordance coeficient (k) to compare the results.

RESULTS:

Main comparisons are DS and DGA, r = 0.71 (0.4 - 0.87); MRA and DGA, r = 0.61 (0.25 - 0.82). After division into surgical vs. non-surgical groups, k = 0.857 (p < 0.0001) between DS and DGA; and k = 0.545 (p = 0.003) between MRA and DGA. Most DS and MRA errors occurred in IC sub-occlusions.

CONCLUSION:

The results suggest that when they are used together, DS and non-contrast MRA may substitute DGA in the evaluation of patients for IC stenosis surgery, except when there is discordance between their results or when the methods show sub-occlusive stenosis
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Artéria Carótida Interna / Angiografia Digital / Estenose das Carótidas / Ultrassonografia Doppler Dupla Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adulto / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Arq. neuropsiquiatr Assunto da revista: Neurologia / Psiquiatria Ano de publicação: 2001 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Ressonância Magnética/BR / PREVILAB/BR / Universidade Federal do Rio de Janeiro/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Artéria Carótida Interna / Angiografia Digital / Estenose das Carótidas / Ultrassonografia Doppler Dupla Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adulto / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês Revista: Arq. neuropsiquiatr Assunto da revista: Neurologia / Psiquiatria Ano de publicação: 2001 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Ressonância Magnética/BR / PREVILAB/BR / Universidade Federal do Rio de Janeiro/BR