Your browser doesn't support javascript.
loading
Influência da qualidade do sono na queda noturna da pressão arterial durante monitorização ambulatorial da pressão arterial / Influence of quality of sleep on the nocturnal decline in blood pressure during ambulatory blood pressure monitoring
Alessi, Alexandre; Alessi, Cristiane Rodrigues; Piana, Edson Rogério; Assis, Márcia; Oliveira, Luciano Rodrigo; Cunha, Cláudio L. Pereira da.
  • Alessi, Alexandre; Universidade Federal do Paraná. Curitiba. BR
  • Alessi, Cristiane Rodrigues; Universidade Federal do Paraná. Curitiba. BR
  • Piana, Edson Rogério; Universidade Federal do Paraná. Curitiba. BR
  • Assis, Márcia; Universidade Federal do Paraná. Curitiba. BR
  • Oliveira, Luciano Rodrigo; Universidade Federal do Paraná. Curitiba. BR
  • Cunha, Cláudio L. Pereira da; Universidade Federal do Paraná. Curitiba. BR
Arq. bras. cardiol ; 78(2): 212-223, Feb. 2002. tab, graf
Artigo em Português, Inglês | LILACS | ID: lil-303906
RESUMO

OBJECTIVE:

To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring.

METHODS:

We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall during sleep associated with a specific questionnaire and an analogical visual scale of tolerance for ambulatory blood pressure monitoring were used to assess usual sleep and sleep on the day of examination. Two specialists in sleep disturbances classified the patients into 2 groups those with normal sleep and those with abnormal sleep.

RESULTS:

Fifty-nine (35 percent) patients comprised the abnormal sleep group. Findings regarding the quality of sleep on the day of ambulatory blood pressure monitoring as compared with those regarding the quality of sleep on a usual day were different and were as follows, respectively total duration of sleep (-12.4±4.7 versus -42.2±14.9 minutes, P=0.02), latency of sleep (0.4±2.7 versus 17±5.1 minutes, P<0.001), number of awakenings (0.1±0.1 versus 1.35±0.3 times, P<0.001), and tolerance for ambulatory blood pressure monitoring (8±0.2 versus 6.7±0.35, P=0.035). An abnormal drop in blood pressure during sleep occurred in 20 (18 percent) patients in the normal sleep group and in 14 (24 percent) patients in the abnormal sleep group, P=0.53.

CONCLUSION:

Ambulatory blood pressure monitoring causes sleep disturbances in some patients, and a positive association between quality of sleep and tolerance for the examination was observed
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Sono / Transtornos do Sono-Vigília / Pressão Sanguínea / Monitorização Ambulatorial da Pressão Arterial Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Sono / Transtornos do Sono-Vigília / Pressão Sanguínea / Monitorização Ambulatorial da Pressão Arterial Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR