Your browser doesn't support javascript.
loading
Study of coronary flow reserve with intravenous use of microbubbles (contrast echocardiography) and adenosine: protocol for clinical application in patients suspected of having coronary heart disease / Estudo da reserva de fluxo coronariano com uso endovenoso de microbolhas (ecocardiografia com contraste) e adenosina. Apresentação de protocolo para aplicação clínica em pacientes com suspeita de doença arterial coronariana
Morcerf, Fernando; Moraes, Alvaro; Carrinho, Marcia; Dohmann, Hans J. F.
  • Morcerf, Fernando; Hospital Pró-Cardíaco. Serviço de Ecocardiografia. Rio de Janeiro. BR
  • Moraes, Alvaro; Hospital Pró-Cardíaco. Serviço de Ecocardiografia. Rio de Janeiro. BR
  • Carrinho, Marcia; Hospital Pró-Cardíaco. Serviço de Ecocardiografia. Rio de Janeiro. BR
  • Dohmann, Hans J. F; Hospital Pró-Cardíaco. Serviço de Ecocardiografia. Rio de Janeiro. BR
Arq. bras. cardiol ; 78(3): 281-298, Mar. 2002. ilus, tab, graf
Artigo em Inglês, Português | LILACS | ID: lil-305035
ABSTRACT

OBJECTIVE:

To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography.

METHODS:

81 pts (64 male, 60+11 years) were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20 percent-1ml, dextrose 5 percent-12ml and deca-fluorobutane gas-8ml) to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg) and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories). 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min), titrated for best myocardial contrast. Triggered (11) second harmonic imaging was used.

RESULTS:

Coronary angiography showed 70 flow limiting (> 75 percent) lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99 percent) related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97 percent) related to flow limiting lesions. It was observed only 4 false results. There were no serious complications.

CONCLUSION:

Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Vasodilatadores / Ecocardiografia / Adenosina / Circulação Coronária / Doença das Coronárias Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Limite: Adulto / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Pró-Cardíaco/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Vasodilatadores / Ecocardiografia / Adenosina / Circulação Coronária / Doença das Coronárias Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Limite: Adulto / Aged80 / Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2002 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Pró-Cardíaco/BR