Your browser doesn't support javascript.
loading
Tratamento de falsos-aneurismas femorais pós-cateterismo cardíaco pela compressão com monitorização pelo ecodoppler a cores / Therapy of Femoral False Aneurysms Following Cardiac Catheterization using Color Doppler Echocardiography
Engelhorn, Carlos A; Picheth, Fernando S; Castro Júnior, Nelson; Dabul Júnior, Nicolau Malluf; Engelhorn, Ana L; Casagrande, Cassiana.
  • Engelhorn, Carlos A; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
  • Picheth, Fernando S; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
  • Castro Júnior, Nelson; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
  • Dabul Júnior, Nicolau Malluf; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
  • Engelhorn, Ana L; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
  • Casagrande, Cassiana; Santa Casa de Misericórdia de Curitiba. PUC-PR. BR
Arq. bras. cardiol ; 68(6): 429-431, Jun. 1997. ilus
Artigo em Português | LILACS | ID: lil-320325
ABSTRACT

PURPOSE:

To evaluate the efficiency of a non-surgical treatment of the femoral false aneurysm following cardiac catheterization using the color Doppler echocardiography monitorization.

METHODS:

From August 1993 to October 1996, 17 patients were evaluated by the color Doppler echocardiography, 7 women and 10 men, between 58 and 77 years of age, with the diagnosis of femoral false aneurysms after cardiac catheterization. All the cases were selected for therapy with this new technique, that consisted of the compression of the false aneurysm with the transducer of the ultrasound device and monitorization of the evolution of the false aneurysm thrombosis, through image observation in real time, on the equipment monitor.

RESULTS:

There were 17 selected patients, 16 were successfully treated, requiring an average of 30 minutes of compression with consequent thrombosis of the false aneurysm, without recurrence in 30 days of follow-up. No complications with the use of this technique were noted and the hospitalization period was, on average, 1 day.

CONCLUSION:

This technique is efficient, safe and should be the first choice for the therapy of patients with femoral aneurysm following cardiac catheterization.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cateterismo Cardíaco / Falso Aneurisma / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 1997 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Santa Casa de Misericórdia de Curitiba. PUC-PR/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Cateterismo Cardíaco / Falso Aneurisma / Artéria Femoral Tipo de estudo: Estudo observacional Limite: Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 1997 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Santa Casa de Misericórdia de Curitiba. PUC-PR/BR