Contrast sensitivity to angular frequency gratings is not higher than to Cartesian gratings
Zana, Y; Cavalcanti, A. C. G. T.
  • Zana, Y; Universidade Federal de Pernambuco. Departamento de Psicologia. Recife. BR
  • Cavalcanti, A. C. G. T; Universidade Federal de Pernambuco. Departamento de Psicologia. Recife. BR
Braz. j. med. biol. res ; 37(2): 227-234, Feb. 2004. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-354171
ABSTRACT
When contrast sensitivity functions to Cartesian and angular gratings were compared in previous studies the peak sensitivity to angular stimuli was reported to be 0.21 log units higher. In experiments carried out to repeat this result, we used the same two-alternative forced-choice paradigm, but improved experimental control and precision by increasing contrast resolution from 8 to 12 bits, increasing the screen refresh rate from 30 Hz interlaced to 85 Hz non-interlaced, linearizing the voltage-luminance relation, modulating luminance in frequencies that minimize pixel aliasing, and improving control of the subject's exposure to the stimuli. The contrast sensitivity functions to Cartesian and angular gratings were similar in form and peak sensitivity (2.4 cycles per visual degree (c/deg) and 32 c/360º, respectively) to those reported in a previous study (3 c/deg and 32 c/360º, respectively), but peak sensitivity to angular stimuli was 0.13 log units lower than that to Cartesian stimuli. When the experiment was repeated, this time simulating the experimental control level used in the previous study, no difference between the peak sensitivity to Cartesian and angular stimuli was found. This result agrees with most current models that assume Cartesian filtering at the first visual processing stage. The discrepancy in the results is explained in part by differences in the degree of experimental control.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estimulação Luminosa / Sensibilidades de Contraste Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2004 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pernambuco/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estimulação Luminosa / Sensibilidades de Contraste Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2004 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pernambuco/BR