Your browser doesn't support javascript.
loading
Evaluation of the tensile bond strenght between an aluminous ceramic and two resin cements using the microtensile bond strength test / Avaliação da resistência adesiva entre uma cerâmica aluminizada para infraestrutura e dois cimentos resinosos pelo ensaio de microtração
Leite, Fabíola Pessôa Pereira; Andreatta Filho, Osvaldo Daniel; Valandro, Luiz Felipe; Lopes, Angela Guidini; Kimpara, Estevão Tomomitsu.
  • Leite, Fabíola Pessôa Pereira; UNESP. Faculdade de Odontologia. São José dos Campos. BR
  • Andreatta Filho, Osvaldo Daniel; 1UNESP. Faculdade de Odontologia. São José dos Campos. BR
  • Valandro, Luiz Felipe; Universidade Santa Maria. Santa Maria. BR
  • Lopes, Angela Guidini; UNESP. Faculdade de Odontologia. São José dos Campos. BR
  • Kimpara, Estevão Tomomitsu; UNESP. Faculdade de Odontologia. São José dos Campos. BR
Ciênc. odontol. bras ; 8(1): 6-14, jan.-mar. 2005. tab
Artigo em Inglês | LILACS, BBO | ID: lil-428121
RESUMO
The present study evaluated the union resistance among the surface of the ceramic Procera All CeramÒ (NOBEL BIOCARE) and two different types of resin cements (Panavia F, KurarayÒ e Relyx, 3MÒ).Two ceramic blocks were made with dimensions of 6x6x5mm following the technical guide lines wich were duplicated in composite resin (W3D MASTERÒ). One of the faces of the ceramic block (6mmx5mm) was sandblasted with the Rocatec systemÒ and cemented with the two different cements under constant load of 750g to the correspondents faces composite blocks. After the storage of the samples (seven days in distilled water at 37°) each group formed by ceramic, cement and resin was split up in two axis X and Y and it were obtained specimens with adehive area of 1 mm² ± 0,1. Two groups (n=27) were obtained PanaviaF group and RelyX group. Each sample was fixed with cyanocrylate in an adapted device which was attached to a universal testing machine (EMIC) and then subjected to tensile forces at a crosshead of 0,5 mm/min and load cell of 10kgf. The results showed that the medium values of rupture (MPa) for the PanaviaF group (median=17,011 ± standart deviation=4,131) are statistically different comparing to RelyX group (median 10,071 ± standart deviation 3,550) (p-value=0,001). The conclusion of this study was that the Panavia F had better adhesive resistance than RelyX. All fractures analyzed occurred at the adhesive interface, with no findings of cohesive fracture of the porcelain
Assuntos
Buscar no Google
Índice: LILACS (Américas) Assunto principal: Resistência à Tração / Cerâmica / Resinas Compostas / Cimentos de Resina / Materiais Dentários Idioma: Inglês Revista: Ciênc. odontol. bras Assunto da revista: Odontologia Ano de publicação: 2005 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: 1UNESP/BR / UNESP/BR / Universidade Santa Maria/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Resistência à Tração / Cerâmica / Resinas Compostas / Cimentos de Resina / Materiais Dentários Idioma: Inglês Revista: Ciênc. odontol. bras Assunto da revista: Odontologia Ano de publicação: 2005 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: 1UNESP/BR / UNESP/BR / Universidade Santa Maria/BR