Your browser doesn't support javascript.
loading
Use of magnitude-squared coherence to identify the maximum driving response band of the somatosensory evoked potential
Infantosi, A. F. C; Melges, D. B; Tierra-Criollo, C. J.
  • Infantosi, A. F. C; Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-graduação de Engenharia. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Melges, D. B; Universidade Federal do Rio de Janeiro. Coordenação dos Programas de Pós-graduação de Engenharia. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Tierra-Criollo, C. J; Universidade Federal de Minas Gerais. Escola de Engenharia. Departamento de Elétrica. Grupo de Engenharia Biomédica. Belo Horizonte. BR
Braz. j. med. biol. res ; 39(12): 1593-1603, Dec. 2006. ilus, tab
Artigo em Inglês | LILACS | ID: lil-439685
ABSTRACT
The present study proposes to apply magnitude-squared coherence (MSC) to the somatosensory evoked potential for identifying the maximum driving response band. EEG signals, leads [Fpz'-Cz'] and [C3'-C4'], were collected from two groups of normal volunteers, stimulated at the rate of 4.91 (G1 26 volunteers) and 5.13 Hz (G2 18 volunteers). About 1400 stimuli were applied to the right tibial nerve at the motor threshold level. After applying the anti-aliasing filter, the signals were digitized and then further low-pass filtered (200 Hz, 6th order Butterworth and zero-phase). Based on the rejection of the null hypothesis of response absence (MSC(f) > 0.0060 with 500 epochs and the level of significance set at a = 0.05), the beta and gamma bands, 15-66 Hz, were identified as the maximum driving response band. Taking both leads together ("logical-OR detector", with a false-alarm rate of a = 0.05, and hence a = 0.0253 for each derivation), the detection exceeded 70 percent for all multiples of the stimulation frequency within this range. Similar performance was achieved for MSC of both leads but at 15, 25, 35, and 40 Hz. Moreover, the response was detected in [C3'-C4'] at 35.9 Hz and in [Fpz'-Cz'] at 46.2 Hz for all members of G2. Using the "logical-OR detector" procedure, the response was detected at the 7th multiple of the stimulation frequency for the series as a whole (considering both groups). Based on these findings, the MSC technique may be used for monitoring purposes.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Tempo de Reação / Nervo Tibial / Eletroencefalografia / Potenciais Somatossensoriais Evocados Tipo de estudo: Estudo prognóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR / Universidade Federal do Rio de Janeiro/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Tempo de Reação / Nervo Tibial / Eletroencefalografia / Potenciais Somatossensoriais Evocados Tipo de estudo: Estudo prognóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Braz. j. med. biol. res Assunto da revista: Biologia / Medicina Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR / Universidade Federal do Rio de Janeiro/BR