Correlação das características do ecodoppler do sistema porta com presença de alterações endoscópicas secundárias à hipertensão porta em pacientes com cirrose hepática / Correlation of Doppler ultrasound of the portal system with endoscopic changes caused by portal hypertension in cirrhotic patients / Correlation of Doppler ultrasound of the portal system with endoscopic changes caused by portal hypertension in cirrhotic patients
Arq. gastroenterol
; Arq. gastroenterol;43(3): 178-183, jul.-set. 2006. ilus, graf, tab
Article
em Pt, En
| LILACS
| ID: lil-439778
Biblioteca responsável:
BR1.1
RESUMO
RACIONAL A hipertensão portal é a causa principal das complicações da cirrose hepática, traduzidas clinicamente por circulação colateral visível na parede abdominal, ascite e varizes esofágicas. OBJETIVO:
Avaliar a capacidade do ecodoppler do sistema porta no diagnóstico de alterações esôfago-gástricas endoscópicas secundárias à hipertensão porta em pacientes com cirrose hepática. PACIENTES EMÉTODOS:
Cento e oitenta e seis pacientes dos ambulatórios de gastroenterologia e hepatologia do Hospital de Clínicas da Universidade Federal do Paraná, Curitiba, PR, foram selecionados para avaliação. Destes, 145 completaram todas as etapas e 133 puderam ser incluídos na análise final dos dados. Todos foram submetidos a endoscopia digestiva alta, visando determinar presença e grau de varizes esofágicas e gástricas e de gastropatia congestiva e ao ecodoppler do sistema porta para medir/aferir pico de velocidade sistólica da veia porta, diâmetro das veias porta e esplênica, tamanho do baço, presença de recanalização da veia umbilical e de fluxo hepatofugal.RESULTADOS:
Os pacientes com varizes esofágicas e gástricas tiveram diferença significativa do tamanho do baço quando comparados com os pacientes sem essas alterações. No entanto, a exatidão e a especificidade deste parâmetro não foi adequada. O diagnóstico de gastropatia congestiva pode ser predito de maneira significativa, tanto pelo diâmetro da veia porta, quanto pelo da esplênica e também pelo tamanho do baço. Da mesma forma, todavia, a exatidão e especificidade destes parâmetros foram ruins. As medidas foram validadas pela construção de curvas ROC ("Receiver Operating Characteristic"), cujas áreas sob as curvas foram sempre menores que 0,8.CONCLUSÃO:
Nesta série de pacientes não houve boa correlação dos parâmetros do ecodoppler do sistema porta com a presença das principais alterações endoscópicas (varizes esofágicas, varizes gástricas, gastropatia congestiva) em pacientes com cirrose hepática.ABSTRACT
BACKGROUND:
The portal hypertension in cirrhotic patients is the main cause of this illness complication, that are clinically translated to visible collateral circulation in the abdominal wall, ascites and esophageal varices.AIM:
To evaluate if the portal system echodoppler is able to estimate the presence of esophageal varices, gastric varices and congestive gastropathy in patients with hepatic cirrhosis. PATIENTS ANDMETHODS:
One hundred and eighty six patients of the gastroenterology and hepatology ambulatory of the Clinical Hospital of the Federal University of Paraná, Curitiba, PR, Brazil, had been selected for evaluation. Of those, 145 had completed all the stages of the evaluation and 133 had been enclosed in the final analysis. All had been submitted to high digestive endoscopy for evaluation of esophagogastric varices and congestive gastropathy and then to Doppler ultrasound of the portal system with study of the systolic peak speed of the portal vein, diameter of the portal and splenic vein and spleen size, presence of the umbilical vein recanalization and hepatofugal flow.RESULTS:
The patients with esophagogastric varices had significant difference of the spleen size when compared to patients without these change. However, none of the Doppler ultrasound parameters showed good accuracy and specificity in this group of cirrhotic patients. Congestive gastropathy patients had their diagnosis predict with significant manner not only by the portal and splenic vein diameter but also by the spleen size. Similarly to that described above, they do not have a good accuracy and specificity. These evaluations were validated by the construction of ROC (Receiver Operating Characteristic) curves, whose areas below the curves had always been less than 0,8.CONCLUSION:
There was not a good correlation of the Doppler ultrasound parameters of the portal system to the presence of the main endoscopic alterations (esophagogastric varices and congestive gastropathy) in ...Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Veia Porta
/
Varizes Esofágicas e Gástricas
/
Ultrassonografia Doppler
/
Hipertensão Portal
/
Fígado
/
Cirrose Hepática
Tipo de estudo:
Etiology_studies
/
Prognostic_studies
Limite:
Female
/
Humans
/
Male
Idioma:
En
/
Pt
Revista:
Arq. gastroenterol
Assunto da revista:
GASTROENTEROLOGIA
Ano de publicação:
2006
Tipo de documento:
Article