Influência do posicionamento do fone na audiometria de alta freqüência / Phone positioning influence in high-frequency audiometry
Rev. bras. otorrinolaringol
; Rev. bras. otorrinolaringol;72(5): 691-698, set.-out. 2006. tab
Article
em Pt
| LILACS
| ID: lil-439850
Biblioteca responsável:
BR1.1
RESUMO
Pesquisas apontam que a audiometria tonal de altas freqüências é um instrumento de diagnóstico precoce de alterações auditivas provenientes de agentes etiológicos. OBJETIVO:
Verificar possíveis diferenças na avaliação audiométrica de altas freqüências de indivíduos com audição normal em função da pessoa que posiciona o fone de ouvido. CASUíSTICA EMÉTODO:
Estudo clínico e experimental na qual participaram 55 graduandos de uma Universidade do interior paulista, com audição normal. Para cada participante, foram realizadas duas testagens na primeira o avaliador posicionou o fone no participante e na segunda, o próprio participante o fez. Utilizou-se um audiômetro AC40 calibrado para emitir tom puro nas freqüências de 10, 12.5 e 16 khz.RESULTADOS:
A análise estatística por meio do coeficiente kappa (k) verificou a concordância entre as duas formas de posicionamento do fone, tendo como critério o valor de kappa>"0,70. Os resultados obtidos para ambas as orelhas ficaram abaixo desse valor, com média de k=0,50. DISCUSSÃO Os resultados indicaram existência de risco de comprometimento da fidedignidade da avaliação em função da pessoa que ajusta o fone ao ouvido do examinado.CONCLUSÃO:
Ao realizar audiometria deve-se levar em consideração a interferência dessa variável, para obtenção de resultados fidedignos.ABSTRACT
Research considers high frequency tonal audiometry as a tool for the early diagnosis of auditory alterations derived from etiological agents. AIM:
to investigate possible differences in high frequency audiometry of individuals with normal hearing, based on the person who places the earphone. PATIENTS ANDMETHOD:
clinical and experimental study with 55 undergraduate students from a country side branch of the São Paulo State University, with normal hearing, underwent two tests each; for the first, the evaluator positioned the earphone on the participant; for the second one, the participant did it by him/herself. An AC40 audiometer calibrated to emit pure tone was used in the frequencies of 10, 12.5, and 16 kHz.RESULTS:
The kappa(k) coefficient statistical analysis was used to verify the agreement between the two ways of earphone positioning of earphone, bearing a ≥0.70 kappa value as a criterion. Results attained for both ears were below this criterion, with k average of 0.50.DISCUSSION:
results indicate a risk of compromising the exam reliability when the patient him/herself adjusts phone to his/her own ear.CONCLUSION:
when performing audiometric assessment, this variable must be considered in order to attain reliable results.Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Audiometria de Tons Puros
/
Limiar Auditivo
Tipo de estudo:
Screening_studies
Limite:
Adolescent
/
Adult
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. otorrinolaringol
Assunto da revista:
OTORRINOLARINGOLOGIA
Ano de publicação:
2006
Tipo de documento:
Article