ABSTRACT
A method for optimizing the administered activity in Static Nuclear Medicine Studies is validated by comparison with ROC curve. Discriminant analysis of image quality is the applied statistical technique. The constructed linear function owns as dependent parameters, the differentiated levels of image quality obtained by observer's criterion. The percentage of cases correctly classified is analyzed. The minimum value of the administered activity, which permit good image quality, can be proposed from the best results of the parameters selected by the function. The method was tested using planar images from a Jaszczak phantom, acquired under four activities (1088 MBq, 962 MBq, 740 MBq and 562 MBq). Two of the six measured Background-to-Signal ratios (S/B) were the parameters able to construct the function with high correlation respect to the expert criterion. The value of 740 MBq was the optimum after method application. The results were coincident with the application of ROC-analysis.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Controle de Qualidade / Cintilografia / Análise Discriminante / Curva ROC Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Rev. med. nucl. Alasbimn j Assunto da revista: Medicina Nuclear Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil / Cuba Instituição/País de afiliação: Central University of Las Villas/CU / Federal University of Pernambuco/BR / Institute for Sciences and Advanced Technologies/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Controle de Qualidade / Cintilografia / Análise Discriminante / Curva ROC Tipo de estudo: Estudos de avaliação / Estudo prognóstico Limite: Humanos Idioma: Inglês Revista: Rev. med. nucl. Alasbimn j Assunto da revista: Medicina Nuclear Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil / Cuba Instituição/País de afiliação: Central University of Las Villas/CU / Federal University of Pernambuco/BR / Institute for Sciences and Advanced Technologies/CU