Your browser doesn't support javascript.
loading
Reação histopatológica da parede da aorta abdominal ao stent não recoberto / Histopathological reaction of the abdominal aorta wall to non-covered stents
Bombonato, Rubio; Palma, José Honório; Marcondes, José Augusto; Moraes, Aury Nunes de; Rocha, João Luiz da; Martins, Márcio Rodrigo; Tchaick, Rodrigo Mezzalira; Domingos, Júlio; Buffolo, Enio.
  • Bombonato, Rubio; Unifesp. EPM. São Paulo. BR
  • Palma, José Honório; Unifesp. São Paulo. BR
  • Marcondes, José Augusto; UNIFESP. Escola Paulista de Medicina. Hospital São Paulo. São Paulo. BR
  • Moraes, Aury Nunes de; Rocha Laboratory in Criciúma. Criciúma. BR
  • Rocha, João Luiz da; University of Sul Catarinense in Criciúma. Criciúma. BR
  • Martins, Márcio Rodrigo; Universidade do Sul Catarinense. Criciúma. BR
  • Tchaick, Rodrigo Mezzalira; Universidade do Sul Catarinense. Criciúma. BR
  • Domingos, Júlio; Universidade do Sul Catarinense. Criciúma. BR
  • Buffolo, Enio; UNIFESP. Escola Paulista de Medicina. São Paulo. BR
Rev. bras. cir. cardiovasc ; 21(2): 198-205, abr.-jun. 2006. ilus, tab
Artigo em Português | LILACS | ID: lil-447720
RESUMO

OBJETIVO:

Avaliar a reação histopatológica da parede aorta abdominal, em suínos, no nível das artérias renais, na presença de stent metálico não recoberto.

MÉTODO:

Foi estudada histopatologicamente a aorta abdominal de 10 suínos, com peso médio de 86,6 quilos e idade média de 6 meses, submetidos a implante de stent metálico posicionado na aorta, no nível das artérias renais, após 100 dias do implante. Os stents foram liberados por auto-expansão com laparotomia. Os cortes histológicos foram realizados nos seguintes locais 1) transição entre a aorta normal e aorta contendo stent; 2) aorta contendo o stent; 3) porção contendo os óstios das artérias renais, 4) linfonodos periaórticos e, 5) parênquima renal. As lâminas foram coradas pela técnica da hematoxilina e eosina.

RESULTADOS:

Os achados macroscópicos revelaram linfonodomegalia periaórtica; espessamento da parede aórtica; artérias lombares e renais pérvias; estrutura anatômica renal normal. Análises microscópicas, próximas aos stents, evidenciaram espessamento da parede vascular, secundário à fibrose intimal e camada média comprometida com fibrose intersticial. Medidas micrométricas da parede aórtica com o stent, comparada à aorta sem o stent, apresentaram aumento da espessura da parede (75,9 por cento) por hiperplasia da camada íntima secundária à proliferação de fibroblastos; depósitos de colágeno com infiltrado inflamatório e granulomas do tipo corpo estranho.

CONCLUSÃO:

O stent de aço inoxidável descoberto, implantado na aorta de suínos, produziu importante reação inflamatória, com fibrose nas camadas média e íntima, evidenciada pelas análises histopatológicas e a sua presença não comprometeu o estado pérvio da aorta e dos ramos lombares e renais.
ABSTRACT

OBJECTIVE:

To evaluate the histopathological reaction of the abdominal aorta wall in pigs' renal arteries to the presence of non-covered stainless steel stents.

METHODS:

The abdominal aorta of ten pigs (6 months old and weighing 86.6 kg on average) was histopathologically studied 100 days after the implant to a stainless steel stents in the abdominal aorta, with one segment of the stent inplanted in the renal artery. Self-expanding non-covered stents were released by laparotomy. The histological slices were made at the transition from the normal aorta and the aorta containing the stent; the aorta portion containing the stent; the portion with the ostia of renal arteries; periaortic lymph nodes and renal parenchyma. The samples were stained by hematoxylin and eosin technique.

RESULTS:

Macroscopic findings showed periaortic lymphadenopathy, thickened aortic wall, patency of lumbar and renal arteries and normal renal anatomical structure. Microscopic analyses near the stents revealed thickening of vessel wall, secondary to the intima fibrosis, and media layer affected by interstitial fibrosis. Micrometric measurements of aorta wall with the stent, compared to the aortic portion without it, presented a 75.90 percent increasein the total thickness of the wall by thickening of the intima layer secondary to fibroblast proliferation, collagen deposits with lymphocitary inflammatory infiltrate and foreign body-type granulomas.

CONCLUSION:

The non-covered stainless steel stent in pigs' aortas produced a significant inflammatory reaction with fibrosis in the media and intima layers evidenced by histopathological analyses; their presence did not interfere in the patency of the abdominal aorta or the renal and lumbar arteries.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aorta Abdominal / Aneurisma da Aorta Abdominal Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Rocha Laboratory in Criciúma/BR / UNIFESP/BR / Unifesp/BR / Universidade do Sul Catarinense/BR / University of Sul Catarinense in Criciúma/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aorta Abdominal / Aneurisma da Aorta Abdominal Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Rocha Laboratory in Criciúma/BR / UNIFESP/BR / Unifesp/BR / Universidade do Sul Catarinense/BR / University of Sul Catarinense in Criciúma/BR