Avaliação experimental de novo eletrodo para implante de marca-passo em fetos / Experimental assessment of a new electrode for fetal pacing
Assad, Renato Samy; Thomas, Petrônio Generoso; Valent, Acrísio Sales; Costa, Roberto; Barbero-Marcial, Miguel; Oliveira, Sérgio Almeida de.
  • Assad, Renato Samy; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Thomas, Petrônio Generoso; Instituto do Coração de Ipatinga. Ipatinga. BR
  • Valent, Acrísio Sales; Hospital Universitário de Fortaleza. Fortaleza. BR
  • Costa, Roberto; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Barbero-Marcial, Miguel; Universidade de São Paulo. Faculdade de Medicina. São Paulo. BR
  • Oliveira, Sérgio Almeida de; USP. FM. HC. Instituto do Coração. São Paulo. BR
Rev. bras. cir. cardiovasc ; 21(3): 272-282, jul.-set. 2006. ilus, graf
Artigo em Português | LILACS | ID: lil-447738
RESUMO
OBJETIVO: O bloqueio atrioventricular total (BAVT) fetal apresenta mau prognóstico quando associado à hidropisia. O implante de marca-passo pode melhorar as chances de sobrevida fetal. Este estudo analisa as características eletrofisiológicas do novo eletrodo de marca-passo fetal, a hemodinâmica e metabolismo fetal sob freqüências cardíacas variadas. MÉTODO: O novo eletrodo (formato de "T") foi implantado no coração de cinco fetos de cabras. O débito cardíaco fetal foi medido com fluxômetro. O BAVT foi obtido por meio da crioablação do nó atrioventricular fetal. Os parâmetros eletrofisiológicos, hemodinâmica e metabolismo fetal foram analisados sob diversas freqüências cardíacas. RESULTADOS: O eletrodo fetal apresentou baixos limiares agudos, sem falhas no comando do estímulo. A curva do limiar de estimulação permaneceu relativamente constante para larguras de pulso acima de 0,5 mseg. A resistência foi de 1050,4 ± 76,6 ohms; e a onda R foi de 8,6 ± 5,6 mV. A freqüência cardíaca fetal abaixo de 60 bpm produziu baixo débito cardíaco fetal e hipotensão arterial (p<0,05). A bradicardia fetal ocasionou queda da saturação de oxigênio paralela à queda do débito cardíaco fetal, sendo mais grave abaixo de 60 bpm. CONCLUSÃO: O novo eletrodo permite um procedimento menos invasivo e uma fixação miocárdica estável, evitando-se o deslocamento do eletrodo após a recuperação da atividade fetal. Os limiares obtidos são compatíveis com uma estimulação crônica estável e segura. Este estudo sugere a freqüência cardíaca inicial de 80 bpm pós-implante, com posterior aumento gradual, o que permitirá um aumento adequado do débito cardíaco e uma situação mais adaptativa.
ABSTRACT
OBJECTIVE: The prognosis of congenital complete heart block (CHB) is very poor when manifested with fetal hydrops. Fetal pacing may improve the survival rate. This study aims to assess the electrophysiological characteristics of a new lead, as well as fetal hemodynamic and metabolism under different fetal heart rates. METHODS: The new lead (T-shaped) was deployed into the myocardium of five fetal goats. Fetal cardiac output was measured by a flow transducer. CHB was achieved by cryosurgical ablation of fetal AV node. Electrophysiological parameters, hemodynamic and metabolic behavior of the fetus under different fetal heart rates were evaluated. RESULTS: The acute stimulation thresholds were consistently low. The voltage strength-duration curve remained relatively constant at pulse widths > 0.5 msec. The stimulation resistance was 1050.4 ± 76.6 ohms, and the sensed fetal R wave was 8.6 ± 5.6 mV. Fetal heart rate bellow 60 bpm was associated to low cardiac output and low blood pressure (p<0.05). Fetal bradycardia also determined oxygen saturation drop parallel to low cardiac output, with severe hypoxia below 60 bpm. CONCLUSION: The new lead allows for a less invasive procedure and stable fixation to the myocardium that may prevent lead dislodgement after fetal recovery. It seems to be compatible with safe chronic stimulation. This study suggests that a gradual increase in the fetal rate beginning on 80 bpm after implantation would be more adaptive and adequately augment fetal cardiac output.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Hidropisia Fetal / Bloqueio Cardíaco Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Universitário de Fortaleza/BR / Instituto do Coração de Ipatinga/BR / USP/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Hidropisia Fetal / Bloqueio Cardíaco Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Português Revista: Rev. bras. cir. cardiovasc Assunto da revista: Cardiologia / Cirurgia Geral Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Universitário de Fortaleza/BR / Instituto do Coração de Ipatinga/BR / USP/BR / Universidade de São Paulo/BR