Your browser doesn't support javascript.
loading
Testes de pista para avaliação da capacidade lática de corredores velocistas de alto nível / Track test to assess the lactic ability in high level runners
De-Oliveira, Fernando Roberto; Lima-Silva, Adriano Eduardo; Nakamura, Fábio Yuzo; Kiss, Maria Augusta Peduti Dal' Molin; Loch, Monique da Silva Gevaerd.
  • De-Oliveira, Fernando Roberto; Universidade do Estado de Santa Catarina. Centro de Educação Física e Desportos. Laboratório de Pesquisa Morfo-Funcional. Florianópolis. BR
  • Lima-Silva, Adriano Eduardo; Universidade do Estado de Santa Catarina. Centro de Educação Física e Desportos. Laboratório de Pesquisa Morfo-Funcional. Florianópolis. BR
  • Nakamura, Fábio Yuzo; Universidade Estadual de Londrina. Centro de Educação Física e Desportos. Grupo de Estudo e Pesquisa em Metabolismo, Nutrição e Exercício. BR
  • Kiss, Maria Augusta Peduti Dal' Molin; Universidade de São Paulo. Escola de Educação Física e Esporte. Laboratório de Desempenho Esportivo. São Paulo. BR
  • Loch, Monique da Silva Gevaerd; Universidade do Estado de Santa Catarina. Centro de Educação Física e Desportos. Laboratório de Pesquisa Morfo-Funcional. Florianópolis. BR
Rev. bras. med. esporte ; 12(2): 99-102, mar.-abr. 2006. tab, graf
Artigo em Português | LILACS | ID: lil-450178
RESUMO
A capacidade anaeróbia (CAn) é dada pelo somatório das capacidades alática e lática (CLa). Em cicloergômetro, tem sido utilizado teste de esforço máximo de 30 segundos (max30) para a aproximação da CAn (potência média e índice de fadiga). Atualmente, a CLa não é diretamente medida, necessitando de abordagens operacionalizáveis, como a medida de performance e a concentração sanguínea de lactato ([La]). Com corredores velocistas de alto nível, espera-se que, em esforço de maior duração, i.e. 60 segundos (max60), ocorra uma maior exigência da CLa e que, por validade ecológica, deve ser aplicado em pista. O objetivo do presente estudo foi comparar as variáveis derivadas de max30 e max60 em velocistas. Oito atletas de nível nacional e internacional (19-27 anos) foram submetidos aos testes de corrida max30 e max60, em pista sintética oficial e coleta de sangue arterializado do lóbulo da orelha, imediatamente, um, três, cinco, sete e meio e 10 minutos após o esforço. Para comparação entre max30 e max60 foi utilizado o teste t de Student e a correlação simples de Pearson para verificação da associação entre as variáveis. As concentrações de lactato foram significativamente maiores em max60 do que em max30 (20,9 ± 1,2 vs 18,2 ± 1,9mM, p < 0,05). Antagonicamente, as velocidades médias foram significativamente menores (7,9 ± 0,2 vs 9,1 ± 0,2m.s-1; respectivamente). Correlações significantes foram encontradas entre as velocidades em max30 e max60 (r = 0,92; p < 0,05); entretanto, o mesmo não aconteceu para o lactato (r = 0,62; p > 0,05). Pelas características destes atletas, que possuem grande tolerância às elevadas [La], variáveis derivadas de testes com duração/distância próximas aos 60s/500m parecem mais adequados como índices de CLa.
ABSTRACT
The anaerobic ability (AnA) is given by the sum of the alactic and lactic (AlA) ability. The cycloergonometer has been used at the maximal 30-second strength (max30) to the AnA approach (mean power and fatigue index). Presently, the AnA is not directly measured, and it is required an operational approaching, such as the measurement of the performance and the blood lactate concentration ([La]). In high-level velocity runners, it is expected that on long-endurance, that is, 60 seconds (max30) strength there would be a higher AnA demand, and aiming the ecological validity, it must be applied on the track. The purpose of this study was to make a comparison between the derived variables of the (max30) and (max60) in runners. Eight male national and international 19-27 years old athletes were submitted to max30 and max60 running tests on an official synthetic track, where it was performed an arterialized blood collection from the ear lobule immediately 1, 3, 5, 7.5, and 10 minutes after the strength. To make a comparison between the max30 and the max60, it was used the t-Student test and the simple Pearson's correlation to check the association between variables. The lactate concentrations were significantly higher at max60 than at max30 (20.9 ± 1.2 vs. 18.2 ± 1.9 mM, p < 0.05). Oppose to this, the mean velocities were significantly lower (7.9 ± 0.2 vs. 9.1 ± 0.2 m.s-1, respectively). Significant correlations were found between max30 and max60 (r = 0.92; p < 0.05). However, it was not seen the same as to the lactate (r = 0.62; p > 0.05). According to these athletes' characteristics, who are highly tolerant to elevated [La], the derived test variables with duration/distance close to the 60 s/500 m seem to be more adequate as AnA indexes.
RESUMEN
La capacidad anaerobica (CAn) se da por la suma de la capacidad aláctica y láctica (el CLa). En el cicloergómetro, la prueba de esfuerzo máximo de 30 segundos (max30) se ha usado para el acercamiento de CAn (la potencia média y el índice de fatiga). Ahora, la CLa no es directamente medido, mientras se necesitando el accionar las aproximaciones como son la medida de la actuación y la concentración sanguínea de lactato ([La]). Con corredores esprínteres de nivel alto, se ha esperado que, en el esfuerzo de duración más grande, es decir 60 segundos (el max60), se pase a una demanda más grande del CLa, y que para la validez ecológica, debe aplicarse en la pista. El objetivo del estudio presente fue el de comparar las variables derivadas de max30 y max60 en los esprínteres. Ocho atletas de nivel internacional y nacional (19-27 años) se sometieron a las pruebas de max30 de la carrera máxima y max60, en pista sintética oficial con recolección de sangre arteriolizado del lóbulo aricular, inmediatamente, a los uno, tres, cinco, siete y medio y diez minutos después del esfuerzo. Para la comparación entre el max30 y max60 la prueba de t de Student y la correlación simple de Pearson se usaron para la comprobación de la asociación entre ambas variables. Las concentraciones del lactato eran significativamente más grandes en el max60 que en el max30 (20,9 ± 1,2 contra 18,2 ± 1,9 mm, p < 0,05). Antagónicamente, las velocidades eran significativamente más pequeñas (7,9 ± 0,2 contra 9,1 ± 0,2 m.s¹; respectivamente). Se encontraron correlaciones significantes entre las velocidades en el max30 y max60 (r = 0,92; p < 0,05), sin embargo, no pasó lo mismo para el lactato (r = 0,62; p > 0,05). Para las características de estos atletas se define que pose una gran tolerancia a los altos [La], las variables derivadas de pruebas con el duración/distancia íntimo a los 60s/500m parecen más apropiadas para los índices de CLa.
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resistência Física / Corrida / Limiar Anaeróbio / Ácido Láctico / Teste de Esforço Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR / Universidade do Estado de Santa Catarina/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resistência Física / Corrida / Limiar Anaeróbio / Ácido Láctico / Teste de Esforço Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR / Universidade do Estado de Santa Catarina/BR