Your browser doesn't support javascript.
loading
Avaliação da influência do tempo e do diâmetro na obstrução da janela pleuropericárdica / Evaluation of the influence of time and diameter on the patency of TH pericardial window
Puntel, Vitório Moscon; Boasquevisque, Carlos Henrique Ribeiro; Falcão, Pedro Gustavo; Haddad, Rui; Marsico, Giovanni Antônio.
  • Puntel, Vitório Moscon; UFRJ. Rio de Janeiro. BR
  • Boasquevisque, Carlos Henrique Ribeiro; UFRJ. Faculdade de Medicina. Rio de Janeiro. BR
  • Falcão, Pedro Gustavo; Centro Universitário de Volta Redonda. Volta Redonda. BR
  • Haddad, Rui; UFRJ. Faculdade de Medicina. Rio de Janeiro. BR
  • Marsico, Giovanni Antônio; UFRJ. Rio de Janeiro. BR
Rev. Col. Bras. Cir ; 34(2): 98-104, mar.-abr. 2007. tab
Artigo em Português | LILACS | ID: lil-450977
RESUMO
OBJETIVO: Avaliar a influência do diâmetro e do tempo na obstrução da janela pleuro-pericárdica em cães com pericárdio normal. MÉTODO: Trinta e seis cães mestiços foram divididos em seis grupos: 1 a, 1 b,1 c, 2 a, 2 b, 2 c; n=6 por grupo. Nos grupos 1 a , 1 b, 1 c, à janela foi de 2cm de diâmetro e nos grupos 2 a, 2 b, 2 c, foi de 4cm. Os animais foram reoperados respectivamente após 2, 8 e 12 semanas. Na re-operação, avaliou-se o grau de obstrução através de uma escala de aderência pericárdio-epicárdica e a histopatologia das bordas do pericárdio. RESULTADOS: Numa análise global, observou-se 89 por cento de janelas abertas e 11 por cento de janelas totalmente obstruídas. No grupo com 2cm de diâmetro original, na reoperação, encontrou-se um diâmetro maior em 89 por cento dos cães, enquanto que nos cães com janela original de 4cm, isto ocorreu em 61 por cento. Quando comparou-se os resultados nos cães com janelas de diâmetro igual, mas re-operados em diferentes tempos de pós-operatório, não se observou diferença estatisticamente significante. O mesmo ocorreu quando comparou-se os cães com janelas de diâmetro diferente e re-operados em tempos iguais de pós-operatório. O grau de aderência pericárdio-epicárdica, de acordo com a escala de gradação, não foi diferente entre os vários grupos em função do tempo e diâmetro com exceção do grupo com janela de 4cm e re-operado com 8 semanas (Grupo 2b). As alterações histopatológicas não foram estatisticamente significantes entre os grupos. Em nenhum cão observou-se obstrução da janela pleuropericárdica pelo pulmão. CONCLUSÃO: o tempo e o diâmetro da janela pleuropericardica não influenciaram na obstrução da mesma.
ABSTRACT
BACKGROUND: to evaluate the influence of diameter and time on the patency of transthoracic pericardial window in normal pericardium. METHODS: Thirty-six mongrel dogs were divided into 6 groups: 1a, 1b and 1c; 2a, 2b and 2c; n=6 per group. In groups 1a, 1b and 1c the pericardial window diameter was 2cm and in groups 2a, 2b and 2c it was 4cm. Animals were sacrificed 2, 8 and 12 weeks , respectively and we evaluated the patency and histology of the pericardial margins. RESULTS: Eighty-nine per cent of the windows were open and 11 percent were completely obstructed by pericardial-epicardic adhesions. In the groups with a 2cm-pericardial window, we observed during sacrifice an increase of the original diameter in 89 percent of the animals. In dogs with a 4cm-pericardial window a greater diameter was observed in 61 percent of the animals. We did not observe statistical differences comparing animals with the same window diameter but sacrificed at different time points. Likewise, we did not observe differences among dogs with different window diameters but sacrificed at the same time points. The degree of pericardial-epicardic adhesions, according to a graduation score, was not different among the groups when analyzing the influence of time and diameter, except for the group 2b ( 4cm-window diameter and animals sacrificed at 8 weeks). Histopatology was not different among the different groups. We did not observe any lung blockade of the transthoracic pericardial windows. CONCLUSIONS: time and diameter did not influence the patency of the transthoracic pericardial window.
Texto completo: DisponíveL Índice: LILACS (Américas) Idioma: Português Revista: Rev. Col. Bras. Cir Assunto da revista: Cirurgia Geral Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Universitário de Volta Redonda/BR / UFRJ/BR