Your browser doesn't support javascript.
loading
Aplicação de medidas cefalométricas em 3D-TC / Application of cephalometric measurements in 3D-TC
Lopes, Patrícia de Medeiros Loureiro; Perrella, Andréia; Moreira, Carla Ruffeil; Rino Neto, José; Cavalcanti, Marcelo Gusmão Paraiso.
  • Lopes, Patrícia de Medeiros Loureiro; Universidade Cidade de São Paulo. São Paulo. BR
  • Perrella, Andréia; Universidade de São Paulo. Faculdade de Odontologia. São Paulo. BR
  • Moreira, Carla Ruffeil; Universidade de São Paulo. Faculdade de Odontologia de Bauru. Bauru. BR
  • Rino Neto, José; USP. FO. Departamento de Ortodontia e Odontopediatria. São Paulo. BR
  • Cavalcanti, Marcelo Gusmão Paraiso; Universidade de São Paulo. Faculdade de Odontologia. São Paulo. BR
Rev. dent. press ortodon. ortopedi. facial ; 12(4): 99-106, 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-460931
RESUMO

OBJETIVO:

o objetivo desta pesquisa foi avaliar a precisão e acurácia (validade) de medidas cefalométricas lineares em imagens reconstruídas em terceira dimensão (3D), pela técnica de volume, a partir da tomografia computadorizada (TC) multislice.

METODOLOGIA:

o material da pesquisa consistiu de 10 (dez) crânios secos, previamente selecionados, sem distinção de etnia ou gênero, os quais foram submetidos à TC multislice 16 cortes com 0,5mm de espessura por 0,3mm de intervalo de reconstrução. Posteriormente, os dados obtidos foram enviados para uma estação de trabalho independente, contendo o programa Vitrea®. Os pontos cefalométricos (n=13) foram localizados e as respectivas medidas ósseas lineares (n=15) foram realizadas por 2 examinadores, previamente treinados, medindo cada um duas vezes, independentemente, em 3D. As medidas físicas foram obtidas por um terceiro examinador, utilizando um paquímetro digital. A análise dos dados foi realizada mediante um estudo comparativo entre as medidas inter e intra-examinadores, em 3D-TC, e entre estas e as medidas físicas obtidas diretamente nos crânios, utilizando ANOVA (análise de variância).

RESULTADOS:

não foram encontradas diferenças estatisticamente significantes entre os valores das medidas inter e intra-examinadores, nem entre as medidas físicas e em 3D, com p>0,6 para todas as medidas. O erro percentual foi de 2,05 por cento para as medidas interexaminadores e de 2,11 por cento para as medidas intra-examinadores. A média do erro percentual entre as medidas físicas e em 3D variou de 0,96 por cento a 1,47 por cento.

CONCLUSÃO:

todas as medidas cefalométricas lineares foram consideradas precisas e acuradas utilizando a técnica de volume em 3D por meio da TC multislice.
ABSTRACT

AIM:

To test the precision and accuracy of conventional linear cephalometric measurements in 3D reconstructed images using a multislice CT.

METHODS:

The study population consisted of 10 dry skulls, previously selected, without distinction of ethnic group and sex, which were submitted to a multislice CT 16 slices using 0.5mm of slice thickness and 0.3mm of interval of reconstruction. Subsequently the data was sent to an independent workstation. Conventional craniofacial landmarks (n=13), usually applied to facial orthopedic and orthodontic treatment planning, were localized and linear measurements (n=15) were obtained by 2 radiologists, twice each, independently, in 3D-CT images. In total 600 measurements were made. The correspondent physical measurements were obtained by a third examiner using a digital caliper. Statistical evaluation of the measurements was carried out regarding to inter and intra-examiner, in 3D-CT, and between image and physical measurements from dry skulls, using analysis of variance. RESULTS AND

CONCLUSIONS:

There were no statistically significant differences between inter and intra-examiner measurements or between imaging and physical measurements. The results also showed an inter-examiner variability error of 2.05 percent, and an intra-examiner variability error of 2.11 percent. There were also no statistically significant differences between imaging and physical measurements with p>0.6 for all measurements. The mean difference was from 0.96 percent to 1.47 percent for all measurements. The validity of linear cephalometric measurements was established using 3D volume rendering from a multislice CT with high precision and accuracy.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Tomografia Computadorizada por Raios X / Cefalometria Idioma: Português Revista: Rev. dent. press ortodon. ortopedi. facial Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR / Universidade Cidade de São Paulo/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Tomografia Computadorizada por Raios X / Cefalometria Idioma: Português Revista: Rev. dent. press ortodon. ortopedi. facial Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: USP/BR / Universidade Cidade de São Paulo/BR / Universidade de São Paulo/BR