Your browser doesn't support javascript.
loading
Análise da espessura macular pela tomografia de coerência óptica no edema macular refratário de origem diabética após aplicação de triancinolona intravítrea / Macular thickness analysis by optic coherence tomography in refractory diabetic macular edema treated with intravitreous triamcinolone
Pinheiro, Alexandre; Serracarbassa, Pedro Durães; Maia Júnior, Otacílio Oliveira; Takahashi, Walter Yukihiko.
  • Pinheiro, Alexandre; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Setor de Retina e Vítreo. São Paulo. BR
  • Serracarbassa, Pedro Durães; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Setor de Retina e Vítreo. São Paulo. BR
  • Maia Júnior, Otacílio Oliveira; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Setor de Retina e Vítreo. São Paulo. BR
  • Takahashi, Walter Yukihiko; Universidade de São Paulo. Faculdade de Medicina. Hospital das Clínicas. Setor de Retina e Vítreo. São Paulo. BR
Arq. bras. oftalmol ; 70(5): 784-789, set.-out. 2007. graf, tab
Artigo em Português | LILACS | ID: lil-470095
RESUMO
OBJETIVO: Avaliar o efeito da aplicação intravítrea de triancinolona na espessura macular medida pela tomografia de coerência óptica (Stratus-OCT), pressão intra-ocular e acuidade visual no tratamento do edema macular diabético não responsivo ao tratamento prévio com fotocogulação a laser, no período de 6 meses. MÉTODOS: Foram estudados 21 indivíduos (22 olhos) submetidos a exame oftalmológico completo, medida da acuidade visual, pressão intra-ocular e análise pela tomografia de coerência óptica, tratados previamente com no mínimo 2 sessões de laser. Os indivíduos participantes do estudo foram tratados com aplicação intravítrea de acetato triancinolona na dose de 4 mg / 0,1 ml. As visitas de acompanhamento foram agendadas no 1º dia pós-aplicação, 1º, 3º e 6º meses. Foram estudados o resultado visual e anatômico assim como as possíveis complicações relacionadas com o procedimento da aplicação intravítrea. RESULTADOS: O estudo demonstrou redução significativa da espessura macular média analisada pelo OCT nos 1º, 3º e 6º meses pós-aplicação (p=0,001), acompanhado de melhora da acuidade visual média (p<0,001). A espessura macular central média ± DP na primeira visita foi de 399 ± 121 µm e diminuiu em 39,9 por cento (239 ± 53 µm) no primeiro mês (p<0,001), 35,5 por cento (255 ± 93 µm) no terceiro mês (p<0,001) e 18,1 por cento (326 ± 135 µm) no sexto mês (p=0,001). A melhora da acuidade visual média foi de 18 e 16 letras na tabela ETDRS nos 3º e 6º meses respectivamente. As complicações relatadas foram o aumento da pressão intra-ocular em 7 olhos (33,3 por cento casos). CONCLUSÕES: Foi observada redução da média das espessuras da retina ao longo de todo o tempo de acompanhamento, com aumento significante da espessura macular entre o 3º e 6º mês. Foi observado melhora estatisticamente significante da média da acuidade visual ao final do acompanhamento, porém não houve melhora entre o 3º e 6º mês.
ABSTRACT
PURPOSE: To assess the effect of intravitreal injections of triamcinolone on macular thickness (Stratus-OCT), intra-ocular pressure and visual acuity, in the treatment of diabetic macular edema non-responsive to previous laser photocoagulation, over a 6-month period. METHODS:The study included 21 subjects (22 eyes) who underwent complete ophthalmologic examination, measurements of visual acuity and intraocular pressure, and OCT, previously treated with at least 2 laser applications. The study participants were treated with 4 mg / 0.1 ml intravitreal triamcinolone. Follow-up visits were scheduled for the 1st day after treatment, and after 1, 3 and 6 months. Visual and anatomical results, as well as possible complications associated with the intravitreal injection procedure were studied. RESULTS: The study showed a significant reduction in mean macular thickness, assessed by OCT at 1, 3 and 6 months post-treatment (p=0.001), combined with an improvement of the mean visual acuity (p<0.001). Central macular thickness mean ± SD value on the first visit was 399 (±121 µm); it was reduced by 39.9 percent (239 ± 53 µm) at the first month (p<0.001), 35.5 percent (255 ± 93 µm) at the third month (p<0.001), and 18.1 percent (326 ± 135 µm) at the sixth month (p=0.001). The improvement in mean visual acuity was of 18 and 16 letters on the ETDRS table, on the 3rd and 6th month, respectively. Reported complications were an increase in intraocular pressure in seven eyes (33.3 percent of the cases). CONCLUSIONS: A reduction in mean retinal thickness was observed throughout the entire follow-up period, with significant increase in macular thickness between the 3rd and 6th month. The mean visual acuity showed statistically significant improvement at the end of the follow-up period, but no change was noticed between the 3rd and 6th month.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Retina / Triancinolona Acetonida / Edema Macular / Fotocoagulação a Laser / Retinopatia Diabética / Glucocorticoides Tipo de estudo: Estudo observacional / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Retina / Triancinolona Acetonida / Edema Macular / Fotocoagulação a Laser / Retinopatia Diabética / Glucocorticoides Tipo de estudo: Estudo observacional / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade de São Paulo/BR