Diagnóstico auxiliado por computador na detecção de nódulos pulmonares pela tomografia computadorizada com múltiplos detectores: estudo preliminar de 24 casos / Detection of pulmonary nodules by computer-aided diagnosis in multidetector computed tomography: preliminary study of 24 cases
J. bras. pneumol
;
34(1): 27-33, jan. 2008. ilus, tab
Artigo
em Português
| LILACS
| ID: lil-474294
RESUMO
OBJETIVOS:
Avaliar o desempenho de um programa para auxílio na detecção de nódulos pulmonares em tomografia computadorizada com múltiplos detectores (TCMD).MÉTODOS:
Foram avaliadas 24 tomografias computadorizadas de tórax consecutivas realizadas no Centro de Medicina Diagnóstica Fleury no período de 07/10/2006 a 19/10/2006 usando um tomógrafo helicoidal multidetectores de 64 canais. O estudo compreendeu 12 pacientes do sexo feminino e 12 do sexo masculino, com idades variando entre 35 e 77 anos, idade média de 57,9. As imagens foram analisadas independentemente pelo método da dupla leitura e pelo programa diagnóstico auxiliado por computador (DAC). Os nódulos encontrados nos diferentes processos foram registrados e os dados comparados.RESULTADOS:
A sensibilidade total da detecção de nódulos pelo DAC nesse trabalho foi de 16,5 por cento, 55 por cento excluindo os nódulos medindo <4 mm. A sensibilidade separada por tamanho foi de 6,5 por cento para nódulos <4 mm, 45 por cento para nódulos de 4 a 6 mm, 100 por cento para nódulos de 6 mm a 1 cm, e 0 por cento para nódulos >1 cm. Menos de 1 por cento dos nódulos verdadeiros destacados pelo DAC não haviam sido registrados no processo de dupla leitura.CONCLUSÕES:
Neste trabalho preliminar de 24 casos, o programa testado não conseguiu superar de forma significativa a sensibilidade da dupla leitura realizada de rotina neste serviço.ABSTRACT
OBJECTIVES:
To evaluate the performance of a computer program designed to facilitate the detection of pulmonary nodules using multidetector computed tomography (MDCT) scans of the chest.METHODS:
We evaluated 24 consecutive MDCT scans of the chest at the Fleury Diagnostic Imaging Center during the period from October 7 to October 19 of 2006, using a 64-channel CT scanner. The study comprised 12 females and 12 males, ranging from 35 to 77 years of age (mean, 57.9 years). Double reading and a computer-aided diagnosis (CAD) system were used in order to perform two independent analyses of the data. The nodules found using both methods were recorded, and the data were compared.RESULTS:
The total sensitivity of CAD for the detection of nodules was 16.5 percent, increasing to 55 percent when nodules <4 mm in diameter were excluded. Sensitivity by diameter was 6.5 percent for nodules <4 mm, 45 percent for nodules of 4-6 mm, 100 percent for nodules of 6 mm-10 cm, and 0 percent for nodules >1 cm. More than 99 percent of true nodules detected by CAD were registered in the image double reading process.CONCLUSIONS:
In this preliminary 24-case study, the sensitivity of computer program tested was not significantly greater than that of the double-reading process that is routinely performed in this facility.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Interpretação de Imagem Assistida por Computador
/
Tomografia Computadorizada por Raios X
/
Nódulo Pulmonar Solitário
Tipo de estudo:
Estudo diagnóstico
/
Estudos de avaliação
Limite:
Adulto
/
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Português
Revista:
J. bras. pneumol
Assunto da revista:
Pneumologia
Ano de publicação:
2008
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Centro de Medicina Diagnóstica Fleury/BR
/
Universidade Federal de São Paulo/BR
Similares
MEDLINE
...
LILACS
LIS