Resultado funcional e índice macular em portadores de buraco macular submetidos à cirurgia com remoção da membrana limitante interna / Functional outcome and macular index in macular hole patients who underwent surgery with internal limiting membrane removal
Arq. bras. oftalmol
;
71(2): 182-186, mar.-abr. 2008. graf, tab
Artigo
em Português
| LILACS
| ID: lil-483024
RESUMO
OBJETIVOS:
Avaliar o resultado funcional e o índice macular dos portadores de buraco macular submetidos à cirurgia com remoção da membrana limitante interna.MÉTODOS:
Quinze olhos de 15 pacientes com buraco macular estágios 2, 3 e 4 foram incluídos no estudo. Todos foram submetidos à cirurgia de buraco macular convencional com remoção da membrana limitante interna corada pelo azul de tripan. Melhor acuidade visual com correção e cortes transversais medidos por tomografia de coerência óptica (OCT) foram avaliados no pré- e pós-operatório. O índice macular (razão entre a altura e base do buraco macular) foi calculado e correlacionado com o diâmetro mínimo do buraco macular e o ganho de acuidade visual pós-operatória.RESULTADOS:
Obteve-se fechamento do buraco macular em todos pacientes operados. Em 86,7 por cento, houve ganho de pelo menos três linhas de visão. O índice macular demonstrou correlação negativa significante com o diâmetro mínimo (r=0,811). Não foi observada correlação significante entre o índice macular e o ganho de acuidade visual pós-operatória (r=0,351).CONCLUSÃO:
Os resultados funcionais na cirurgia do buraco macular com remoção da membrana limitante interna foram bons neste grupo de pacientes. O índice macular demonstrou ser compatível com a configuração espacial do buraco macular, porém não foi preditor de resultados visuais.ABSTRACT
PURPOSE:
To evaluate the functional outcome and macular index in patients with macular hole who underwent surgery with internal limiting membrane removal.METHODS:
Fifteen eyes of 15 patients with idiopathic macular hole stages 2, 3 or 4 were enrolled in this study. All patients underwent conventional macular hole surgery with trypan blue staining to remove the internal limiting membrane. The best-corrected visual acuity and cross-sectional images of macular hole measured by optical coherence tomography (OCT) were evaluated pre- and postoperatively. The macular hole index (ratio of hole height to base diameter of the hole) was calculated and correlated with minimum diameter of the macular hole and postoperative gain in visual acuity.RESULTS:
Macular hole closure was observed in all operated patients. In 86.7 percent, there was a visual gain of at least three lines. Macular hole index was significantly negative correlated with the minimum diameter of the macular hole (r=0.811). There was no significant correlation between macular index and postoperative gain in visual acuity (r=0.351).CONCLUSION:
Functional outcomes with internal limiting membrane removal were good in this group of patients. Macular index was compatible with spatial configuration of the macular hole, however visual outcomes were not predictable.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Perfurações Retinianas
/
Membrana Basal
/
Acuidade Visual
Tipo de estudo:
Estudo observacional
/
Estudo prognóstico
/
Fatores de risco
Limite:
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Português
Revista:
Arq. bras. oftalmol
Assunto da revista:
Oftalmologia
Ano de publicação:
2008
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
FAV/BR
/
Fundação Altino Ventura/BR
/
Hospital de Olhos de Pernambuco/BR
Similares
MEDLINE
...
LILACS
LIS