Avaliação por imagem nos candidatos ao implante coclear: correlação radiológico-cirúrgica / Evaluation by imaging methods of cochlear implant candidates: radiological and surgical correlation
Lima Júnior, Luiz Rodolpho Pena; Rocha, Marina David; Walsh, Priscilla Vargas; Antunes, Camila André; Calhau, Clara Maria Dias Ferreira.
  • Lima Júnior, Luiz Rodolpho Pena; Clínica Otocento. BR
  • Rocha, Marina David; Universidade Federal do Rio Grande do Norte. BR
  • Walsh, Priscilla Vargas; Universidade Federal do Rio Grande do Norte. BR
  • Antunes, Camila André; Universidade Federal do Rio Grande do Norte. BR
  • Calhau, Clara Maria Dias Ferreira; Clínica Otocento. BR
Rev. bras. otorrinolaringol ; 74(3): 395-400, maio-jun. 2008. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-487057
RESUMO
No pré-operatório da cirurgia de Implante Coclear (IC) o estudo por imagem adquire importância fundamental, proporcionando ao cirurgião segurança na indicação e realização da cirurgia. A avaliação ideal compreende a associação entre Tomografia Computadorizada (TC) e Ressonância Nuclear Magnética (RNM).

OBJETIVO:

Avaliar a acurácia dos exames de imagem como preditores de possíveis complicações durante o ato cirúrgico. Desenho do Estudo Corte transversal. MATERIAL E

MÉTODOS:

Foram avaliados por prontuários, 104 pacientes submetidos à cirurgia de IC de maio de 2003 a outubro de 2006. Estes passaram por uma seleção multidisciplinar pré-operatória, e radiológica por TC associada ou não à RNM.

RESULTADOS:

Excluiu-se 4 pacientes sem registro de exames radiológicos, resultando 100 pacientes. Estes foram divididos em dois grupos grupo A (TC) apresentou acurácia 69,69 por cento, sensibilidade 36,36 por cento; especificidade 86,36 por cento; Valor Preditivo Positivo (VPP) 57,14 por cento; Valor Preditivo Negativo (VPN) 73,07 por cento e o B (TC e RNM) acurácia 80,59 por cento, sensibilidade 38,46 por cento; especificidade 90,74 por cento; VPP 50,0 por cento; VPN 85,96 por cento.

CONCLUSÕES:

A avaliação radiológica pré-operatória do IC mostrou-se importante, sendo capaz de identificar alterações anatômicas, evitando, ou ao menos, preparando o cirurgião para possíveis complicações. Esse estudo demonstrou que a avaliação associada com TC e RNM pôde ser considerada superior à TC isoladamente.
ABSTRACT
Evaluation by imaging methods is critical in the preoperative care of cochlear implant (CI) surgery, providing safety to surgeons when indicating and performing this procedure. The ideal imaging study consists of an association between Computed Tomography (CT) and Magnetic Resonance Imaging (MRI).

AIM:

To investigate the accuracy of imaging studies as predictors of possible complications of surgery. Study

Design:

A cross-sectional investigation. MATERIAL AND

METHOD:

The medical records of 104 patients undergoing CI surgery between May 2003 and October 2006 were studied. The preoperative muldisciplinary selection process included CT associated or not with MRI.

RESULTS:

The final sample was composed of 100 patients after 4 patients with no records of radiological exams were excluded. Patients were divided into two groups. The accuracy of group A (CT only) was 69.69 percent, the sensitivity was 36.36 percent, the specificity was 86.36 percent, the Positive Predictive Value (PPV) was 57.14 percent, and the Negative Predictive Value (NPV) was 73.07 percent; the accuracy of group B (CT and MRI) was 80.59 percent, the sensitivity was 38.46 percent, the specificity was 90.74 percent, the PPV was 50.0 percent, and the NPV was 85.96 percent.

CONCLUSION:

The preoperative radiological evaluation by CI was effective in identifying anatomic abnormalities, allowing surgeons to avoid, or at least be aware of, possible complications. This study demonstrated that CT and MRI were superior to CT alone.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Implante Coclear / Surdez / Complicações Intraoperatórias Tipo de estudo: Estudo observacional / Estudo de prevalência / Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Rev. bras. otorrinolaringol Assunto da revista: Otorrinolaringologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Clínica Otocento/BR / Universidade Federal do Rio Grande do Norte/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Implante Coclear / Surdez / Complicações Intraoperatórias Tipo de estudo: Estudo observacional / Estudo de prevalência / Estudo prognóstico Limite: Feminino / Humanos / Masculino Idioma: Inglês / Português Revista: Rev. bras. otorrinolaringol Assunto da revista: Otorrinolaringologia Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Clínica Otocento/BR / Universidade Federal do Rio Grande do Norte/BR