Precisão e confiabilidade de um localizador apical na odontometria de molares inferiores: estudo in vitro / Accuracy and reliability of an apex locator for working length determination of lower molars: an in vitro study
Brito Júnior, Manoel; Soares, Janir Alves; Camilo, Carla Cristina; Oliveira, Alba Moura.
  • Brito Júnior, Manoel; Faculdades Unidas do Norte de Minas. BR
  • Soares, Janir Alves; Faculdades Unidas do Norte de Minas. BR
  • Camilo, Carla Cristina; s.af
  • Oliveira, Alba Moura; Universidade Federal dos Vales do Jequitinhonha e Mucuri. BR
Rev. odonto ciênc ; 22(58): 293-298, out.-dez. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-487207
RESUMO
O presente estudo in vitro teve por objetivo avaliar a precisão e a confibialidade de um modelo de localizador apical eletrônico (LAE) na obtenção do comprimento de trabalho (CT) em molares inferiores. Após adequado acesso endodôntico e manobras iniciais de exploração em 20 dentes, mediu-se com uma lima K # 10 o comprimento dos condutos mésio-vestibular (MV) e distal (D) até o forame apical, subtraindo-se 1 mm (CT1), tendo como referências externas as cúspides mésio-vestibular e disto-vestibular, respectivamente. Os dentes foram fixados em recipientes plásticos contendo alginato procedendo-se as medidas eletrônicas com o LAE Novapex (Fórum,Israel). Limas K # 10 foram inseridas nos canais MV e D até que os instrumentos atingissem a marca 0 no visor do aparelho e posteriormente realizava-se o recuo até a marca 1, ajustando-se os cursores nas mesmas referências externas do CT1. As mensurações com o LAE foram realizadas em triplicata, adotando-se a média das medidas, por dois operadores calibrados, um estudante de gradução (CT2) e um especialista em endodontia (CT3). O coeficiente de correlação linear de Pearson revelou alta concorcândia inter?operadores e intraoperadores. Para comparação do CT1, CT2 e CT3 foi aplicado o Teste t de Student para amostras pareadas (p < 0,05), que não mostrou diferenças significativas entre todas as medidas odontométricas para os canais radiculares MV (p = 0,22 ) e D (p = 0,94). Portanto, o LAE testado mostrou-se preciso e confiável na determinação da odontometria de molares inferiores.
ABSTRACT
The aim of this in vitro study was to evaluate the accuracy and reliability of an electronic apex locator (EAL) in the determination of the working length (WL) of lower molars. After appropriate endodontic access and exploration in 20 teeth, it was measured with a size 10 K-file the actual canal length (AL) of the mesio-buccal (MB) and distal (D) root canals until the apical foramen. Next, it was subtracted 1mm of the AL (WL1), taking as coronal references the vertex of the mesio-buccal and disto-buccal cusps. The teeth were embedded in an alginate model and electronic tooth length measurements were carried out using the EAL Novapex (Fórum, Israel). A 10 K-type file was inserted down the MB and D canals until EAL indicated that the file had reached the apex retreating until the mark 1. The cursors were adjusted in the same external references of WL1. The eletronic measurements were obtained by two operators, a graduate student (WL2) and a specialist (WL3). Three measurements were taken and an average recorded. The coefficient of Pearson revealed high concordance level inter-operators and intra-operators. For comparison of WL1, WL2 and WL3 the test t of Student was applied (p < 0,05). There was no statistically significant difference between all the measures for MB (p = 0,22) and D (p = 0,94) root canals. Therefore, the tested EAL was accurate and reliable in the determination of the WL of lower molars.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Técnicas In Vitro / Odontometria Tipo de estudo: Estudos de avaliação Limite: Humanos Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdades Unidas do Norte de Minas/BR / Universidade Federal dos Vales do Jequitinhonha e Mucuri/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Técnicas In Vitro / Odontometria Tipo de estudo: Estudos de avaliação Limite: Humanos Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdades Unidas do Norte de Minas/BR / Universidade Federal dos Vales do Jequitinhonha e Mucuri/BR