Your browser doesn't support javascript.
loading
Influência do método de polimerização na microdureza de compósitos microhíbridos armazenados em água destilada / Influence of curing method on the micro hardness of microhybrid composites immersed in distilled water
Herbstrith Segundo, Regênio Mahfuz; Mota, Eduardo Gonçalves; Oshima, Hugo Mitsuo Silva; Balbinot, Carlos Eduardo; Bondan, João Lopes; Coelho, Luis Felipe Butzke.
  • Herbstrith Segundo, Regênio Mahfuz; s.af
  • Mota, Eduardo Gonçalves; PUCRS. Porto Alegre. BR
  • Oshima, Hugo Mitsuo Silva; PUCRS. Porto Alegre. BR
  • Balbinot, Carlos Eduardo; s.af
  • Bondan, João Lopes; s.af
  • Coelho, Luis Felipe Butzke; s.af
Rev. odonto ciênc ; 22(58): 317-320, out.-dez. 2007. graf, tab
Artigo em Português | LILACS | ID: lil-487211
RESUMO
O objetivo do presente estudo é comparar e avaliar a microdureza Vickers de um compósito restaurador microhíbrido ativado por dois tipos de unidades polimerizadoras e armazenados em água destilada. Trinta espécimes foram feitos com resina Charisma B1, para cada um dos regimes de polimerização fotopolimerização por luz halógena, fotopolimerização por LED e fotopolimerização mais ciclo adicional em autoclave. Foram feitas duas leituras de microdureza Vickers por corpo de prova em 1 dia, 7 dias e 14 dias de imersões. O ciclo adicional de polimerização mostrou uma tendência de aumentar os valores de microdureza dos compósitos restauradores, não mostrando diferenças estatisticamente significantes entre LED e Luz Halógena (p > 0,05).
ABSTRACT
The purpose of this study is to evaluate and compare the Vickers microhardness of one microhybrid composite polymerized with different sources and stored in distilled water for up to 14 days. Thirty samples have been prepared with Charisma composite, shade B1, for each polymerization

method:

halogen light photopolymerization, LED photopolymerization, photopolymerization plus post-cured cycles in autoclave. Two readings of Vichers micro hardness have been done in each sample on 24h, 7days and 14 days of storage. The post curing method tended to improve the microhardness, but it was not statistically different from halogen or LED curing methods (p > 0.05). After 7 days, the hardness values were higher than the first day, but statistically not different to 14 days (p < 0.05). Post-cured samples in autoclave had an improved mean value, however, without differing from those of the LED and halogen.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas Tipo de estudo: Estudos de avaliação Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: PUCRS/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas Tipo de estudo: Estudos de avaliação Idioma: Português Revista: Rev. odonto ciênc Assunto da revista: Odontologia Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: PUCRS/BR