Your browser doesn't support javascript.
loading
Esterilização em Ortodontia: eficácia do esterilizador com esferas de vidro / Sterilization in Orthodontics: effectiveness of glass bead sterilizers
Dutra, Sônia Rodrigues; Santos, Vagner Rodrigues; Menezes, Leonardo Foresti Soares de; Drummond, Alexandre Fortes; Vilaça, Ênio Lacerda; Couto, Paulo Henrique Amêndola.
  • Dutra, Sônia Rodrigues; UFMG. FO. BR
  • Santos, Vagner Rodrigues; UFMG. FO. Departamento de Clínica, Patologia e Cirurgia. BR
  • Menezes, Leonardo Foresti Soares de; UFMG. FO. BR
  • Drummond, Alexandre Fortes; UFMG. FO. BR
  • Vilaça, Ênio Lacerda; UFMG. FO. Departamento de Odontologia Restauradora. BR
  • Couto, Paulo Henrique Amêndola; UFMG. FO. BR
Rev. dent. press ortodon. ortopedi. facial ; 13(4): 60-66, jul.-ago. 2008. ilus
Artigo em Português | LILACS | ID: lil-487765
RESUMO

OBJETIVO:

avaliar a efetividade do esterilizador com esferas de vidro Steri® 350, quanto ao controle de infecção das partes ativas dos alicates ortodônticos.

METODOLOGIA:

foram utilizados nove alicates ortodônticos, previamente esterilizados em autoclave à temperatura de 121ºC, durante 20 minutos. Posteriormente, as partes ativas dos alicates foram contaminadas com Bacillus stearothermophilus. Logo após, as pontas dos alicates foram colocadas no Steri® 350, durante os períodos de 3, 5, 10, 15, 20, 30 e 40 segundos, em temperatura de 255ºC, para avaliar a eficácia da esterilização. RESULTADOS E

CONCLUSÕES:

o esterilizador com esferas de vidro mostrou-se eficaz no controle do crescimento de Bacillus stearothermophilus nas partes ativas dos alicates ortodônticos, a partir de 10 segundos de exposição à temperatura de 255ºC.
ABSTRACT

AIM:

The aim of this research was to evaluate the efficiency of Steri® 350glass bead sterilizer, on the infection control of the active part of the orthodontic pliers.

METHODS:

Nine orthodontic pliers were sterilized in the steam autoclave at 121ºC in 20 minutes and subsequently the active part of each plier was dipped in a culture for Bacillus stearothermophilus. Later, the active part of each plier was putted into the Steri® 350 in the following periods 3, 5, 10, 15, 20, 30, and 40 seconds at 255ºC to evaluate the efficiency of this method in the infection control. RESULTS AND

CONCLUSIONS:

This sterilization method has been effective to control the presence of Bacillus stearothermophilus on the active part of orthodontic pliers at 255ºC in 10 seconds.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Ortodontia / Esterilização Idioma: Português Revista: Rev. dent. press ortodon. ortopedi. facial Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UFMG/BR

Similares