Your browser doesn't support javascript.
loading
Reprodutibilidade no teste de uma repetição máxima no exercício de puxada pela frente para homens / Reproducibility in the maximal repetition test in the lat pulldown exercise for men
Barros, Marcos André Pereira de; Sperandei, Sandro; Silveira Júnior, Paulo César Soter; Oliveira, Carlos Gomes de.
  • Barros, Marcos André Pereira de; Instituto de Ciências da Atividade Física. Rio de Janeiro. BR
  • Sperandei, Sandro; UFRJ. COPPE. Programa de Engenharia Biomédica. Rio de Janeiro. BR
  • Silveira Júnior, Paulo César Soter; Instituto de Ciências da Atividade Física. Rio de Janeiro. BR
  • Oliveira, Carlos Gomes de; Universidade Salgado de Oliveira. Programa de Pós Graduação em Ciências da Atividade Física. Niterói. BR
Rev. bras. med. esporte ; 14(4): 348-352, jul.-ago. 2008. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-493155
RESUMO

OBJETIVO:

Verificar a reprodutibilidade teste-reteste do teste de uma repetição máxima (1RM) no exercício de puxada pela frente.

MÉTODOS:

26 homens adultos saudáveis e ativos (25 ± 3 anos, 76,8 ± 9,86kg, 177 ± 5,3cm, 12,5 ± 4,25 por cento de gordura) assinaram consentimento antes de participar deste estudo. A coleta de dados foi feita em dois dias, separados por 48-72 horas. No primeiro dia, foram coletados dados antropométricos e o teste de 1RM progressivo foi realizado. Em cada tentativa, cargas progressivas de 5kg eram acrescidas até que ocorresse uma falha, quando então a carga era reduzida em três quilos e uma nova tentativa era realizada. Foram respeitados cinco minutos de intervalo entre as tentativas. No segundo dia, o teste de 1RM era repetido seguindo o mesmo protocolo. As cargas máximas dos dois dias foram comparadas utilizando o teste t pareado para o erro sistemático e a técnica de limites de concordância, para 95 por cento do erro aleatório.

RESULTADOS:

O erro médio apresentado pela amostra foi de 2,9 ± 2,48kg, sendo observada diferença significativa entre os dois dias de teste (p < 0,00001). O limite de concordância para 95 por cento do erro ficou entre -1,9 e 7,8kg.

CONCLUSÃO:

Este estudo mostrou tendência a aumento da carga máxima atingida no segundo dia de teste, o que aponta para a necessidade de se considerar tal diferença ao planejar e analisar estudos de força onde o teste de 1RM for utilizado.
ABSTRACT

OBJECTIVE:

To verify the test-retest 1RM reproducibility in the lat pulldown exercise.

METHODS:

Twenty-six healthy and physically actives men (25 ± 3 years, 76.8 ± 9.86 kg, 177 ± 5.3 cm, 12.5 ± 4.25 percent body fat) signed an informed consent before participate in this study. The data was collected in two visits, 48-72 hours apart. During the first visit, anthropometric data was measured and progressive 1RM test was performed. For each attempt progressive loads of 5 kg were added until the fail, when the load was reduced in 3 kg and a last attempt was performed. A five-minute rest was allowed before each attempt. During the second visit, the 1RM test was repeated following the same protocol. The Maximum loads of each day were compared by paired t-test to systematic error and limits of agreement technique to random error was employed.

RESULTS:

The mean error found was 2.9 ± 2.48 kg, being significantly different between days (p<0.00001). The error 95 percent limit of agreement was between -1.9 and 7.8 kg.

CONCLUSION:

This study showed a tendency to an increase in the second-day load, which when planning and analyzing strength training studies using 1RM test.

Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Ciências da Atividade Física/BR / UFRJ/BR / Universidade Salgado de Oliveira/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Tipo de estudo: Ensaio Clínico Controlado Idioma: Português Revista: Rev. bras. med. esporte Assunto da revista: Medicina Esportiva Ano de publicação: 2008 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Instituto de Ciências da Atividade Física/BR / UFRJ/BR / Universidade Salgado de Oliveira/BR