Análisis de las alteraciones de la posición de los dientes artificiales de prótesis totales maxilares en función del tamaño del arco / Analysis of position alterations in artificial teeth of maxillary complete dentures in function of the arch size
Acta odontol. venez
; 45(3): 335-340, 2007. ilus, tab
Article
em Es
| LILACS
| ID: lil-502065
Biblioteca responsável:
AR29.1
RESUMEN
El propósito de este trabajo fue analizar en prótesis totales maxilares la influencia del tamaño de los arcos en el movimiento de dientes artificiales cuando los mismos se someten a las inclusiones con barrera de yeso tipo IV (especial), polimerizado en microondas y medidas gráficamente por computadora. Veinte y una réplicas de prótesis que se habían construido previamente, fueran divididos en tres grupos grupo 1, constituido de 7 prótesis maxilares del tamaño pequeño; grupo 2, constituido de 7 prótesis de tamaño medio y, grupo 3, de gran tamaño. Las prótesis habían sido medidas en puntos demarcados previamente en los dientes, con un programa de computación gráfica, después del encerado y después de la polimerización y demuflado. La diferencia entre la medida, en las dos etapas, demostró la ocurrencia de pequeñas alteraciones. Fue concluido, del punto de vista estadístico, que no ha tenido diferencias significativas en las alteraciones de la posición de dientes, en los tres tamaños de modelos estudiados.
ABSTRACT
The purpose of this study was to evaluate the influence of maxillary arch size on the artificial teeth movement in complete dentures. The maxillary dentures were processed with a barrier-type IV gypsum molding technique, and polymerized by microwave energy. Twenty one dentures were fabricated and equally divided into 3 groups, according to maxillary residual ridge size G1) small; G2) medium and G3) large size. Reference points were made on the incisal edges of the central incisors and the supporting cusps of the premolar and second molar teeth. Linear distances among reference points, in a horizontal plane, were measured with a computer program (Auto cad 2000) before and after processing denture. Although there were differences between measurements, indicating some movement degree among artificial teeth, the results showed no statistical significantly differences among three groups studied. It was concluded that the maxillary arch size has not influence on the artificial teeth position.
Texto completo:
1
Índice:
LILACS
Assunto principal:
Dente Artificial
/
Arcada Parcialmente Edêntula
/
Prótese Total Superior
/
Arcada Osseodentária
/
Maxila
Tipo de estudo:
Prognostic_studies
Limite:
Humans
Idioma:
Es
Revista:
Acta odontol. venez
Assunto da revista:
Medicina Bucal
/
ODONTOLOGIA
/
Sa£de Bucal
Ano de publicação:
2007
Tipo de documento:
Article