Your browser doesn't support javascript.
loading
Troca valvar aórtica com diferentes próteses: existem diferenças nos resultados da fase hospitalar? / Aortic valve replacement with different types of prosthesis: are there differences in the outcomes during hospital phase?
Feguri, Gibran Roder; Macruz, Hugo; Bulhões, Domingos; Neves, Antônio; Castro, Rodrigo Moreira; Fonseca, Luciana da; Baungratz, José Francisco; Silva, José Pedro da.
Afiliação
  • Feguri, Gibran Roder; SBCCV.
  • Macruz, Hugo; SBCCV.
  • Bulhões, Domingos; s.af
  • Neves, Antônio; s.af
  • Castro, Rodrigo Moreira; s.af
  • Fonseca, Luciana da; SBCCV.
  • Baungratz, José Francisco; SBCCV.
  • Silva, José Pedro da; SBCCV.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;23(4): 534-541, out.-dez. 2008. graf, tab
Article em En, Pt | LILACS | ID: lil-506038
Biblioteca responsável: BR1.1
RESUMO

OBJETIVOS:

Analisar dados intra-operatórios e possíveis diferenças na evolução clínica da fase hospitalar de pós-operatório da troca valvar aórtica com diferentes próteses.

MÉTODOS:

Análise de 60 pacientes, divididos em três grupos os submetidos a troca valvar por prótese biológica (20); por prótese mecânica (20); e finalmente, por valva homóloga (20). A média da idade foi de 51,1 anos; 60 por cento eram do sexo masculino e 40 por cento do feminino; 86,7 por cento estavam em NYHA II ou III; 63,3 por cento eram hipertensos, 18,3 por cento diabéticos; a etiologia valvar foi degenerativa em 39 por cento, reumática em 36 por cento e endocardite em 15 por cento.

RESULTADOS:

A mortalidade hospitalar foi de 5 por cento; não houve diferenças entre os grupos na incidência de choque séptico ou cardiogênico, insuficiência renal aguda, arritmias no centro cirúrgico e na unidade de terapia intensiva (UTI), assim como para o tempo de internação na UTI e tempo de ventilação mecânica. Houve diferença estatística nos tempos de circulação extracorpórea (P=0,02) e pinçamento aórtico (P<0,0001) desfavorável aos pacientes com valva homóloga. O tempo de internação na enfermaria foi maior para os pacientes com valva mecânica (P=0,05), assim como o tempo total de internação hospitalar tende a ser maior neste grupo, porém sem significância estatística. Pacientes com hematócrito pré-operatório abaixo de 38,1 por cento utilizaram 2,73 unidades de hemoderivados; e com hematócrito no pós-operatório abaixo de 32 por cento utilizaram 1,79 unidades. Controle ecocardiográfico mostrou mínimas diferenças evolutivas.

CONCLUSÃO:

A utilização de diferentes próteses, nesta amostra, não gerou diferenças nos resultados da fase hospitalar de pós-operatório; O homoenxerto é uma opção viável e com boa aplicabilidade clínica.
ABSTRACT

OBJECTIVE:

To analyze intraoperative data and possible differences in clinical evolution during postoperative hospital phase for aortic valve replacement surgery using different types of prosthesis.

METHODS:

Analysis of 60 patients divided into three groups. Valve replacement with bioprosthesis (20), mechanical prosthesis (20) and homologous valve (20). The mean age was 51.1, 60 percent were male and 40 percent female patients; 86.7 percent were in NYHA II or III; 63.3 percent presented arterial hypertension and 18.3 percent had diabetes. Aetiology of valve disease was degenerative for 39 percent, rheumatic for 36 percent and endocardits for 15 percent.

RESULTS:

The hospital mortality was 5 percent; there were no differences in the incidence of septical or cardiogenic shock, acute renal failure, rhythms disorders during surgery or intensive care, neither for total time in intensive care and mechanical ventilation. However, there was statistical differences as regards the cardiopulmonary bypass total time (P=0.02) and the aortic clamping time (P<0.0001) unfavorable to homograft valve group. The ward admission time was greater for mechanical valve group (P=0.05) as well as for total admission time, but without statistical significance. It was observed that patients with preoperative hematocrit smaller than 38.1 percent used 2.73 units of blood components, and with postoperative hematocrit smaller than 32 percent used 1,79 units of blood components. Echocardiography control showed minimal evolutional differences.

CONCLUSION:

The use of different types of prosthesis for this study does not cause differences in the results of postoperative hospital phase. The use of homograft valve is a feasible option with good clinical applicability.
Assuntos
Palavras-chave
Texto completo: 1 Índice: LILACS Assunto principal: Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Doenças das Valvas Cardíacas Tipo de estudo: Etiology_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Idioma: En / Pt Revista: Rev. bras. cir. cardiovasc Assunto da revista: CARDIOLOGIA / CIRURGIA GERAL Ano de publicação: 2008 Tipo de documento: Article
Texto completo: 1 Índice: LILACS Assunto principal: Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca / Doenças das Valvas Cardíacas Tipo de estudo: Etiology_studies Limite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male Idioma: En / Pt Revista: Rev. bras. cir. cardiovasc Assunto da revista: CARDIOLOGIA / CIRURGIA GERAL Ano de publicação: 2008 Tipo de documento: Article