RESUMO

Introdução:

O uso de pressão positiva contínua em vias aéreas (CPAP) causa modificações hemodinâmicas favoráveis em pacientes com insuficiência cardíaca. Na presença de disfunção ventricular esquerda, mecanismos hemodinâmicos propostos associam seu uso ao aumento do débito cardíaco, através da redução do enchimento e da pressão transmural do ventrículo esquerdo. Estes efeitos talvez colaborem para o sucesso dessa terapia em pacientes com congestão pulmonar. Entretanto, até onde extensa revisão bibliográfica nos permite afirmar, não foram estudados os efeitos hemodinâmicos do CPAP em pacientes com estenose mitral, etiologia comum de congestão pulmonar em alguns países em desenvolvimento.

Objetivos:

Avaliar a resposta hemodinâmica dos pacientes portadores de estenose mitral sintomática durante o uso de CPAP.

Métodos:

Foram incluídos quarenta pacientes portadores de estenose mitral. Os critérios de exclusão foram presença de disfunção ventricular esquerda, de outra valvopatia de grau moderado ou importante, de trombo intracavitário ao ecodopplercardiograma e de doença pulmonar obstrutiva crônica. Os pacientes foram avaliados em 3 condições diferentes 1. condição basal, realizada ar ambiente; 2. uso de CPAP 7 cm H2O e 3. uso de CPAP 14 cm H2O. Foi realizada a medida de pressão arterial invasiva (aorta) e utilizado cateter de artéria pulmonar para a medida da pressão arterial pulmonar e débito cardíaco. Foram coletas amostras de gasometria arterial e venosa central. A variação percentual do volume sistólico (deltaVS) foi calculada tendo o valor na condição basal como 100% e foi correlacionada com as características clínicas, ecodopplercardiográficas, hemodinâmicas e gasométricas da condição basal. Os pacientes foram classificados em 3 grupos grupo I - deltaVS <= -10%, grupo II - deltaVS entre -9,9% e +9,9% e grupo III - deltaVS >= +10%.

Resultados:

Durante a aplicação do CPAP, freqüência cardíaca, pressão arterial sistêmica e pressão arterial pulmonar...
ABSTRACT

Background:

Continuous positive airway pressure (CPAP) impacts hemodynamic changes in heart failure patients by impending cardiac filling and reduces cardiac afterload by reducing left ventricular transmural pressure. These effects may collaborate for the success of this therapy in patients with pulmonary congestion. However, to your knowledge, no study has evaluated the hemodymanic effects of CPAP in patients with mitral stenosis, which is a common etiology of pulmonary congestion in some developing countries.

Objectives:

analyze the effects of CPAP on hemodynamic parameters in patients with symptomatic mitral stenosis.

Methods:

Forty patients with symptomatic mitral stenosis were included. They were monitored by aorta pressure and the insertion of a pulmonary artery catheter. Hemodynamic and gasometrical data were collected in each study period. Patients were evaluated in three study periods. Baseline condition was during spontaneous breathing. We applied CPAP 7 cm H2O in the second period and 14 cm H2O in the last period of the study. Were excluded patients with left ventricular systolic dysfunction, other valvopathy more than mild, and left atrial thrombi assessed by echocardiography and patients with history or symptom of chronic obstructive pulmonary disease. Percentage changes of stroke volume (deltaSV) were calculated with the values at baseline set as 100% and were correlated to clinical, ecocardiographic, hemodynamic and gasometrical data (at baseline). Patients were classified in group I if deltaSV was <= -10%, group II if deltaSV was between -9,9% and +9,9% or group III if deltaSV >= +10%.

Results:

During CPAP use, heart rate, systemic blood pressure and pulmonary artery pressure did not significantly change. At CPAP 7 cmH2O, deltaSV correlated positively with baseline values of diastolic pulmonary artery pressure, pulmonary artery occlusion pressure and mean transmitral gradient. There was no variable capable to distinguish the groups...
Assuntos
Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Volume Sistólico / Pressão Positiva Contínua nas Vias Aéreas / Hipertensão Pulmonar / Estenose da Valva Mitral Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2008 Tipo de documento: Tese

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Volume Sistólico / Pressão Positiva Contínua nas Vias Aéreas / Hipertensão Pulmonar / Estenose da Valva Mitral Tipo de estudo: Estudo diagnóstico Limite: Adulto / Feminino / Humanos / Masculino Idioma: Português Ano de publicação: 2008 Tipo de documento: Tese