Estudo in vitro da degradação da força de elásticos ortodônticos de látex sob condições dinâmicas / In vitro study of the force degradation of latex orthodontic elastics under dynamic conditions
Rev. dent. press ortodon. ortopedi. facial
;
14(2): 95-108, mar.-abr. 2009. ilus, graf, tab
Artigo
em Português
| LILACS
| ID: lil-510381
RESUMO
OBJETIVO:
analisar 3 tamanhos de elásticos ortodônticos de látex (1/8", 3/16" e 5/16"), todos classificados como de força pesada pelos seus fabricantes (Dental Morelli, 3M Unitek Corporation e American Orthodontics).MÉTODOS:
através de um dispositivo desenvolvido, os elásticos foram distendidos a 26mm (simulação da posição de repouso da mandíbula) e imersos em saliva artificial a uma temperatura de 37ºC. A cada minuto foram alongados a 44mm (simulação de movimentos mandibulares) e após 1 segundo voltavam a 26mm. Foram realizadas leituras em intervalos de tempos variados. Nos períodos considerados como horários das refeições (3 vezes ao dia), os elásticos eram retirados do dispositivo e guardados em uma caixa acrílica; e, no período considerado noturno, o dispositivo pneumático era desligado e os elásticos ficavam estirados em 26mm.RESULTADOS:
a degradação maior da força ocorreu nas primeiras 2 horas para toda a amostra.CONCLUSÕES:
concluiu-se que os elásticos apresentaram diferenças estatisticamente significativas em relação à espessura e à largura; e que os elásticos 1/8" devem ser trocados, pelo menos, a cada 24 horas e os elásticos 3/16" e 5/16" podem ser trocados a cada 72 horas, caso se deseje níveis de força próximos aos iniciais.ABSTRACT
AIM:
To analyze 3 sizes of latex orthodontics elastics (1/8", 3/16" and 5/16"), all classified as heavy force by their manufacturers, of the following commercial brands Dental Morelli, 3M Unitek Corporation and American Orthodontics.METHODS:
Through a developed device, the elastics bands were distended 26mm (position of rest of the mandible) and submerged in artificial saliva to 37ºC. Every minute they were prolonged to 44mm (simulation of mandibular movements) and after 1 second they returned to 26mm. Measurements were accomplished in intervals of varied times. In the periods considered as meals time (3 times a day), the elastics bands were removed of the device and kept in an acrylic box, and in the period considered as nocturne the pneumatic device was turned off and the elastics bands were stretched in 26mm.RESULTS:
The larger force degradation happened in the first 2 hours for the whole sample.CONCLUSION:
the elastics bands presented significant statistic differences in relation to thickness and width; and the 1/8" elastics bands should be changed at least every 24 hours and the 3/16" and 5/16" elastic bands can be changed every 72 hours, if force levels similar to the initials are desired.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Ortodontia
/
Técnicas In Vitro
/
Teste de Materiais
/
Materiais Dentários
Idioma:
Português
Revista:
Rev. dent. press ortodon. ortopedi. facial
Ano de publicação:
2009
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
APCD/BR
/
Unicamp/BR
Similares
MEDLINE
...
LILACS
LIS