Endocarditis relacionada a cables de marcapasos o cardiodesfibriladores implantables / Endocarditis of pacemaker or implantable cardioverter-defibrillator leads
Badra Verdú, Mariano G; Contreras, Alejandro E; Bagur, Rodrigo H; Amuchástegui, Luis M.
  • Badra Verdú, Mariano G; Hospital Privado Centro Médico de Córdoba. Servicio de Cardiología.
  • Contreras, Alejandro E; Hospital Privado Centro Médico de Córdoba. Servicio de Cardiología.
  • Bagur, Rodrigo H; Hospital Privado Centro Médico de Córdoba. Servicio de Cardiología.
  • Amuchástegui, Luis M; Hospital Privado Centro Médico de Córdoba. Servicio de Cardiología.
Rev. Fac. Cienc. Méd. (Córdoba) ; 64(2): 45-47, 2007. tab
Artigo em Espanhol | LILACS | ID: lil-511498
RESUMEN
Antecedentes Dentro del síndrome de endocarditis infecciosa, se incluyen la infección de dispositivos endovasculares. el objetivo de la presentación fue avaluar las características clínicas y la evolución de la endocarditis relacionada a dispositivos electrónicos endovasculares. Casos clínicos entre 2002 - 2007 fueron identificados 7 pacientes con edad promedio de 56,5 años. La presentación clínica fue en el 85,7% fiebre de origen desconocido, con un promedio de 28 días de evolución del cuadro. Los germenes aislados fueron estafilococo coagulasa negativo en 6 pacientes y estafilococo aureus en 1 paciente. El tratamiento se baso en la extracción del sistema y terapia antibiótica, salvo 1 caso que solo recibió tratamiento antibiótico. Hubo 2 (28,5%) muertes intrahospitalarias durante el seguimiento.

Conclusión:

La endocarditis relacionada a dispositivos es una entidad con elevada mortalidad. el diagnóstico temprano y la extracción del sistema son de vital importancia para el tratamiento y pronóstico.
ABSTRACT

BACKGROUND:

Infective endocarditis includes the endovascular devices infection. The main objective was to evaluate the clinical characteristics and evolution of the endocarditis related to electronics devices. CASE REPORTS Between 2002 - 2007 periods were identified 7 patients, age average of 56.5 years. The clinical presentation was fever of unknown origin in 85.7%, with a mean of 28 days of evolution. The microbiology isolated was coagulase-negative staphylococci in 6 patients and staphylococcus aureus in 1 patient. The treatment was complete system extraction and antibiotic therapy, except in 1 case that only received antibiotics. There were 2 deaths (28,5%) during in hospital follow-up.

CONCLUSION:

The endocarditis related to devices is a disease with high mortality. Early diagnosis and system extraction are very important for the treatment and prognosis.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Infecções Relacionadas à Prótese / Desfibriladores Implantáveis / Endocardite / Febre de Causa Desconhecida Tipo de estudo: Estudo prognóstico / Estudo de rastreamento Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Fac. Cienc. Méd. (Córdoba) Assunto da revista: Medicina Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Argentina

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Infecções Relacionadas à Prótese / Desfibriladores Implantáveis / Endocardite / Febre de Causa Desconhecida Tipo de estudo: Estudo prognóstico / Estudo de rastreamento Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Fac. Cienc. Méd. (Córdoba) Assunto da revista: Medicina Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Argentina