Your browser doesn't support javascript.
loading
Cinética e variabilidade da freqüência cardíaca mediante exercício físico predominantemente aeróbio: influência da intensidade e do tempo de análise / Kinetics and heart rate variability during aerobic exercise: influence of the intensity and the period of analyze
Rumenig, Eduardo; Bertuzzi, Rômulo Cássio de Moraes; Nakamura, Fábio Yuzo; Franchini, Emerson; Matsushigue, Karin Ayumi; Kiss, Maria Augusta Peduti Dal'molin.
  • Rumenig, Eduardo; Universidade de São Paulo. Escola de Educação Física e Esporte. São Paulo. BR
  • Bertuzzi, Rômulo Cássio de Moraes; Universidade de São Paulo. Escola de Educação Física e Esporte. São Paulo. BR
  • Nakamura, Fábio Yuzo; Universidade Estadual de Londrina. Centro de Educação Física e Esporte. Londrina. BR
  • Franchini, Emerson; Universidade de São Paulo. Escola de Educação Física e Esporte. São Paulo. BR
  • Matsushigue, Karin Ayumi; Pontifícia Universidade Católica do Paraná. BR
  • Kiss, Maria Augusta Peduti Dal'molin; Universidade de São Paulo. Escola de Educação Física e Esporte. São Paulo. BR
Rev. bras. educ. fís. esp ; 21(3): 205-218, jul.-set. 2007. graf, tab
Artigo em Português | LILACS | ID: lil-514189
RESUMO
A proposta desse estudo foi descrever o comportamento cinético da freqüência cardíaca (FC) e como avariabilidade da FC (VFC) associa-se a esse fenômeno. Sete voluntários foram submetidos a um protocolode testes em cicloergômetro, para determinação da capacidade aeróbia (Lan) e da potência aeróbiamáxima. Em cinco visitas subseqüentes, os indivíduos desempenhavam 30 minutos de exercício físicoem carga constante, correspondendo a 25, 50, 75, 100 e 125% do Lan. As respostas cinéticas “on” e“off” cardíacas (FCON e FCOFF) foram analisadas por funções exponenciais. Utilizou-se a análise espectralpara descrever VFC. Para comparação dos coeficientes estimados pelas funções exponenciais, utilizouseANOVA com medidas repetidas, seguido pelo teste “pos-hoc” de Bonferroni. Adotou-se um nível designificância de 5% para todas as análises. A manifestação da fase cardiodinâmica foi observada nossegundos iniciais do esforço. O componente lento foi evidente para FCON em intensidades superiores aoLan75. O “drift” cardíaco também foi observado para intensidades a partir do Lan75. Inversamente, aFCOFF apresentou um comportamento monoexponencial, mesmo em elevados níveis de esforço. Houvediferença entre amplitude da FCOFF (Aoff) no Lan75, no Lan100, constante de tempo da FCOFF (Toff) noLan100 e no Lan125 comparado aos mesmos índices no Lan25 e Lan50. A atividade vagal diminuiu emfunção do exercício, mas elevou-se novamente após a interrupção do mesmo, enquanto a contribuiçãosimpática não apresentou associação com o esforço. A assimetria entre FCON e FCOFF refletem diferençasnas respostas hemodinâmicas e neurais envolvidas no controle cardíaco.
ABSTRACT
The aim of this study was to describe the heart rate kinetics (FC) and how the heart rate variability (VFC) wasassociated with this phenomenon. Seven subjects were submitted to a cycling protocol to determine theanaerobic threshold (Lan) and the maximal aerobic power. In five subsequent tests, the subjects performedthirty minutes of a steady state exercise, corresponding to 25, 50, 75, 100 e 125% of the anaerobic threshold,respectively. The cardiac kinetic responses on and off (FCON e FCOFF) were analyzed using exponential functions.The spectral analysis was used to describe the VFC. The parameters calculated with the exponential functionwere compared using an one - way repeated measures ANOVA, with pos hoc Bonferroni test. All the statisticalprocedures were considered significant at p < 0.05. The cardiodynamic phase was observed during the firstseconds of the effort for all the subjects. The slow component was observed in the FCON at the intensity abovethe Lan75. The cardiac drift was observed at an intensity of Lan75. Inversely, the FCOFF demonstrated a firstexponential function, independently of the level of the effort. There was a significant difference betweenamplitude of the FCOFF at Lan75, Lan100 and time constants of the FCOFF at Lan100 and Lan125 when comparedto the same indices at Lan25 and Lan50. The parasympathetic activity reduced in the beginning of theexercise, but increased after completion, while the sympathetic contribution did not demonstrate anyassociation with the effort. The asymmetry between FCON and FCOFF indicates differences between hemodynamicsand neural responses associated with the cardiac control.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Exercício Físico / Frequência Cardíaca / Cinetocardiografia Tipo de estudo: Estudo de rastreamento Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Rev. bras. educ. fís. esp Assunto da revista: Medicina Esportiva Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifícia Universidade Católica do Paraná/BR / Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Exercício Físico / Frequência Cardíaca / Cinetocardiografia Tipo de estudo: Estudo de rastreamento Limite: Adulto / Humanos / Masculino Idioma: Português Revista: Rev. bras. educ. fís. esp Assunto da revista: Medicina Esportiva Ano de publicação: 2007 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Pontifícia Universidade Católica do Paraná/BR / Universidade Estadual de Londrina/BR / Universidade de São Paulo/BR