Degradação de força dos elásticos ortodônticos intrabucais / Strength degradation of orthodontics intraoral elastics
Carvalho, Paulo Eduardo Guedes; Cotrim-Ferreira, Flávio Augusto; Lima, Ariane Cássia de; Nahás, Ana Carla Raphaelli; Gomes Filho, Wander Vicente.
  • Carvalho, Paulo Eduardo Guedes; UNICID. BR
  • Cotrim-Ferreira, Flávio Augusto; UNICID. BR
  • Lima, Ariane Cássia de; s.af
  • Nahás, Ana Carla Raphaelli; UNICID. BR
  • Gomes Filho, Wander Vicente; UNICID. BR
Odonto (Säo Bernardo do Campo) ; 14(27/28): 19-28, jan.-dez. 2006. graf, tab
Artigo em Português | LILACS, BBO | ID: lil-518540
RESUMO
O objetivo desta pesquisa consistiu em, por meio de um estudo in vitro, avaliar as características de degradação da força de elásticos ortodônticos intrabucais de algumas marcas comerciais disponíveis no mercado, em relação ao tempo de utilização. Realizou-se a medição de força de sessenta e três elásticos ortodônticos de três marcas comerciais distintas, nos tamanhos de 1/8", 3/16", e 5/16" (sete exemplares em cada grupo), durante o período de cinco dias. Os elásticos foram mantidos em um recipiente com água destilada à 37ºC durante todo o experimento, tendo sido medidos em sua força nos seguintes tempos: O, 1, 4, 12, 24, 36 e 120 horas. Os resultados relativos às forças proporcionadas ao início da pesquisa demonstraram severa diferença entre as marcas comerciais. Durante as primeiras 24 horas, verificou-se acentuada degradação da força para todos os grupos estudados, com perda variando entre 9,3% e 22,1%. Após as primeiras 24 horas, houve continuidade na degradação de força, entretanto em proporções menores em todos os grupos. Concluiu-se que os elásticos intrabucais apresentam degradação de força variável entre as marcas comerciais e os tempos de utilização, sendo esta redução da força mais expressiva nas primeiras 24 horas para todos os grupos avaliados.
ABSTRACT
The purpose of this study, as an in vilro experiment of stretching elastic rings of various commercial brands, was to test the differences of the intraoral elastics strength degradation, among different times of use. Sixty-three orthodontic elastics of three commercial brands, of the following sizes 1/8",3/16" and 5/16" (seven specimens each group), had their strenght tested during five days. The elastics were mantained in a recipient fillied with 37ºC distilled water. Each elastic had its strength measured with a dynamometer at times O, 1,4, 12, 24, 36 and 120 hours. Initial strengths reflect a great difference in the intensity among the brands evaluated. In the first 24 hours, there was an accentuated decline in strength for ali the specimens studies, with a loss of force that ranged from 9.3% to 22.1%. Aher the first 24 hours, the decline in strength continued, but in smoother proportions for alI the groups and brands studied. The elastic rings underwent a degradation of strength that varied in accordance with the time of exposure and the commercial brando Elastic rings are not perfect elastic materiaIs, since their strength undergoes significant degradation as soon as they are attached to "the dental arches, irrespectiveof the size and commercial brand used.
Assuntos
Buscar no Google
Índice: LILACS (Américas) Assunto principal: Ortodontia / Teste de Materiais / Elastômeros Idioma: Português Revista: Odonto (Säo Bernardo do Campo) Assunto da revista: Odontologia Ano de publicação: 2006 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: UNICID/BR