Your browser doesn't support javascript.
loading
Utilização de adesivo de fibrina em cirurgias oftalmológicas / Use of fibrin glue in ocular surgery
Pizzol, Melissa Manfroi Dal; Roggia, Murilo Felix; Kwitko, Sérgio; Marinho, Diane Ruschel; Rymer, Samuel.
  • Pizzol, Melissa Manfroi Dal; Hospital de Clínicas de Porto Alegre. Serviço de Oftalmologia. Setor de Córnea e Doenças Externas. Porto Alegre. BR
  • Roggia, Murilo Felix; HCPA. Serviço de Oftalmologia. Porto Alegre. BR
  • Kwitko, Sérgio; HCPA. Serviço de Oftalmologia. Porto Alegre. BR
  • Marinho, Diane Ruschel; HCPA. Serviço de Oftalmologia. Porto Alegre. BR
  • Rymer, Samuel; Universidade Federal do Rio Grande do Sul. Serviço de Oftalmologia. Porto Alegre. BR
Arq. bras. oftalmol ; 72(3): 308-312, May-June 2009. tab
Artigo em Português | LILACS | ID: lil-521463
RESUMO
OBJETIVO: Avaliar as diferentes técnicas cirúrgicas oftalmológicas nas quais se pode utilizar a cola biológica e possíveis complicações relacionadas ao seu uso. MÉTODOS: Estudo de série de casos retrospectivo, não-comparativo. Foram avaliados 161 olhos de pacientes com idade média de 51,8 anos em que foi utilizada cola biológica (Beriplast P® - Aventis Behring, Alemanha) para fixação de tecido ou fechamento incisional. RESULTADOS: Foram avaliados 76 pacientes com pterígio, 4 com ceratoconjuntivite límbica superior, 4 com tumor limbar, 21 com conjuntivocálase, 31 com ceratopatia bolhosa, 7 com deficiência límbica, 6 com queimadura alcalina, 2 com Stevens-Johnson, 5 com catarata e 5 com glaucoma. Complicações foram relatas em 28 casos (17,4 por cento). Descolamento do tecido fixado e granuloma foram as complicações mais frequentes. Descolamento ocorreu em 10 casos (5,6 por cento) (7 em transplante de membrana amniótica em ceratopatia bolhosa, 2 em transplante de conjuntiva autólogo após exérese de pterígio, 1 após transplante de limbo autólogo por Stevens-Johnson). Granuloma ocorreu em 9 casos (5,6 por cento) (5 em pacientes com queimadura alcalina aguda tratados com transplante de membrana amniótica, 1 em paciente com sequela de queimadura tratado com transplante de limbo autólogo e 3 em pacientes após exérese de pterígio tratados com transplante de conjuntiva autólogo). Todas as complicações ocorreram dentro da primeira semana de pós-operatório. CONCLUSÃO: Embora o presente seja retrospectivo e não-comparativo, podemos observar que a utilização do adesivo de fibrina parece ser segura e efetiva, além de apresentar baixas taxas de complicações nas cirurgias de superfície ocular e de segmento anterior.
ABSTRACT
PURPOSE: To evaluate the use of fibrin glue and its complications in different ophthalmic surgeries. METHODS: A retrospective and non-comparative case series study. 161 eyes were evaluated. The mean age was 51.8 years. Fibrin glue (BeriplastTM - Aventis Behring, Germany) was used in all patients for tissue adherence or incisional closure. RESULTS: Main preoperatives diseases were pterygium (76 patients), superior limbic keratoconjunctivitis (4 patients), limbal tumor (4 patients), conjunctivochalasis (21 patients), bullous keratopathy (31 patients), limbal stem cell deficiency (7 patients), alkali injury (6 patients), Stevens-Johnson syndrome (2 patients), cataract (5 patients) and glaucoma (5 patients). Complications occurred in 28 patients (17.4 percent). Detachment of the fixed tissue and granulomatous foreign body reaction were the main complications. Detachment occurred in 10 cases (5.6 percent) (7 in amniotic membrane transplantation in bullous keratopathy, 2 in autologus conjunctival grafting for pterygium surgery, 1 in autologus limbal transplantation in a Stevens-Johnson syndrome). Granulomatous foreign body reaction was described in 9 patients (5.6 percent) (5 in amniotic membrane transplantation due to acute alkali injury, 1 in autologus limbal graft due to chronic burn injury, and 3 in autologus conjunctival transplant due to pterygium surgery). All the complications described occurred in the first week after surgery. CONCLUSION: Despite the limitations related to the retrospective and non-comparative setting, this study suggests that the use of fibrin glue seems to be safe and effective for tissue fixation or incisional closure presenting low rates of complications in ocular surface and anterior segment surgeries.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Procedimentos Cirúrgicos Oftalmológicos / Adesivos Teciduais / Adesivo Tecidual de Fibrina / Oftalmopatias Tipo de estudo: Estudos de avaliação / Estudo observacional Limite: Adolescente / Adulto / Idoso / Aged80 / Criança / Criança, pré-escolar / Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: HCPA/BR / Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Procedimentos Cirúrgicos Oftalmológicos / Adesivos Teciduais / Adesivo Tecidual de Fibrina / Oftalmopatias Tipo de estudo: Estudos de avaliação / Estudo observacional Limite: Adolescente / Adulto / Idoso / Aged80 / Criança / Criança, pré-escolar / Humanos País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Arq. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: HCPA/BR / Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR