Substituição valvar aórtica percutânea para o tratamento da estenose aórtica: experiência inicial no Brasil / Sustitución percutánea de la válvula aórtica para el tratamiento de la estenosis aórtica: experiencia inicial en Brasil / Percutaneous aortic valve replacement for the treatment of aortic stenosis: early experience in Brazil
Perin, Marco Antonio; Brito Júnior, Fábio Sândoli de; Almeida, Breno Oliveira; Pereira, Marco Aurélio M; Abizaid, Alexandre; Tarasoutchi, Flávio; Grube, Eberhard.
  • Perin, Marco Antonio; Hospital Israelita Albert Einstein. São Paulo. BR
  • Brito Júnior, Fábio Sândoli de; Hospital Israelita Albert Einstein. São Paulo. BR
  • Almeida, Breno Oliveira; Hospital Israelita Albert Einstein. São Paulo. BR
  • Pereira, Marco Aurélio M; Hospital Israelita Albert Einstein. São Paulo. BR
  • Abizaid, Alexandre; Hospital Israelita Albert Einstein. São Paulo. BR
  • Tarasoutchi, Flávio; Hospital Israelita Albert Einstein. São Paulo. BR
  • Grube, Eberhard; Hospital Israelita Albert Einstein. São Paulo. BR
Arq. bras. cardiol ; 93(3): 299-306, set. 2009. ilus, tab
Artigo em Inglês, Espanhol, Português | LILACS | ID: lil-529178
RESUMO
FUNDAMENTO A substituição percutânea da valva aórtica para o tratamento da estenose aórtica é uma alternativa disponível e eficaz para pacientes com alto risco cirúrgico, especialmente aqueles com idade avançada e comorbidades.

OBJETIVO:

Os autores relatam a experiência inicial do emprego da endoprótese CoreValve em nosso meio.

MÉTODOS:

Em janeiro de 2008, dois pacientes foram submetidos à substituição percutânea da valva aórtica por estenose aórtica sintomática. Ambos foram selecionados por terem idade avançada (77 e 87 anos), comorbidades e elevado risco cirúrgico (EuroScore 7,7 por cento e 12,1 por cento).

RESULTADOS:

Os implantes percutâneos do dispositivo CoreValve foram realizados com sucesso. Observou-se a ampliação da área valvar (de 0,7 para 1,5 cm² e de 0,5 para 1,3 cm²) e a redução do gradiente transvalvar aórtico (de 82 para 50 mmHg e de 94 para 31 mmHg) imediatamente após a intervenção. Durante a internação hospitalar, houve a necessidade de implantar marca-passos definitivos nos dois pacientes, por bloqueio átrio-ventricular. Aos seis meses, observou-se a queda ainda maior do gradiente transvalvar aórtico (gradiente < 20 mmHg), e a remissão dos sintomas de insuficiência cardíaca (NYHA III para NYHA I).

CONCLUSÃO:

O emprego da endoprótese CoreValve para o tratamento da estenose aórtica mostrou-se factível e com resultados animadores nesta experiência inicial em nosso meio.
ABSTRACT

BACKGROUND:

Percutaneous aortic valve replacement for the treatment of aortic stenosis is an available and efficient alternative for patients at high surgical risk, especially those with advanced age and comorbidities.

OBJECTIVE:

The authors report the first experience made in our midst with the use of the CoreValve endoprosthesis.

METHODS:

In January 2008, two patients underwent percutaneous aortic valve replacement due to symptomatic aortic stenosis. They were selected for being elderly (77 and 87 years) and presenting comorbidities and a high surgical risk (EuroScore 7.7 percent and 12.1 percent).

RESULTS:

Percutaneous implantations of the CoreValve device were successfully performed. Enlargement of the valve area (from 0.7 to 1.5 cm² and from 0.5 to 1.3 cm²) and reduction of the aortic transvalvular gradient (from 82 to 50 mmHg and from 94 to 31 mmHg) were observed immediately after the intervention. During hospital stay, permanent pacemaker implantation was required in both patients due to atrioventricular block. At six months, an even greater drop in the aortic transvalvular gradient (gradient < 20 mmHg) and remission of symptoms of heart failure (NYHA III to NYHA I) were observed.

CONCLUSION:

The use of the CoreValve endoprosthesis for the treatment of aortic stenosis proved to be feasible and showed encouraging results in this early experience made in our midst.
RESUMEN
FUNDAMENTO La sustitución percutánea de la válvula aórtica en el tratamiento de la estenosis aórtica es una alternativa disponible y eficaz para pacientes de alto riesgo quirúrgico, especialmente los de edad avanzada y comorbilidades.

OBJETIVO:

Los autores relatan la experiencia inicial del empleo de la endoprótesis CoreValve en nuestro medio.

MÉTODOS:

En enero de 2008 se sometió a dos pacientes a la sustitución percutánea de la válvula aórtica por estenosis aórtica sintomática. A ambos se les seleccionó por su edad avanzada (77 y 87 años), comorbilidades y alto riesgo quirúrgico (EuroScore 7,7 por ciento e 12,1 por ciento).

RESULTADOS:

Los implantes percutáneos del dispositivo CoreValve se realizaron exitosamente. Se observó la ampliación del área valvular (de 0,7 para 1,5 cm² y de 0,5 para 1,3 cm²) y la reducción del gradiente transvalvular aórtico (de 82 para 50 mmHg e de 94 para 31 mmHg) inmediatamente después de la intervención. Durante la internación hospitalaria se hizo necesario implantar marcapasos definitivos en ambos pacientes, a causa de bloqueo atrioventricular. Se observó seis meses después una queda aún más grande del gradiente transvalvular aórtico (gradiente < 20 mmHg) y la remisión de los síntomas de insuficiencia cardiaca (NYHA III para NYHA I).

CONCLUSIÓN:

El empleo de la endoprótesis CoreValve para el tratamiento de la estenosis aórtica se reveló factible y los resultados, en esa experiencia inicial en nuestro medio, han sido prometedores.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estenose da Valva Aórtica / Implante de Prótese de Valva Cardíaca Limite: Idoso / Aged80 / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Inglês / Espanhol / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estenose da Valva Aórtica / Implante de Prótese de Valva Cardíaca Limite: Idoso / Aged80 / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Inglês / Espanhol / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Israelita Albert Einstein/BR