Your browser doesn't support javascript.
loading
Avaliação de meios de contraste submetidos à radiação ionizante / Evaluation of contrast media submitted to ionizing radiation
Pinho, Kátia Elisa Prus; Gewehr, Pedro Miguel; Silva, Caroline Werner Pereira da; Barison, Andersson; Tilly Júnior, João Gilberto; Soboll, Danyel Scheidegger.
  • Pinho, Kátia Elisa Prus; Universidade Tecnológica Federal do Paraná. Curso de Tecnologia em Radiologia. Curitiba. BR
  • Gewehr, Pedro Miguel; Universidade Tecnológica Federal do Paraná. Curitiba. BR
  • Silva, Caroline Werner Pereira da; Universidade Federal do Paraná. Curitiba. BR
  • Barison, Andersson; Universidade Federal do Paraná. Departamento de Química. Curitiba. BR
  • Tilly Júnior, João Gilberto; Universidade Federal do Paraná. Hospital de Clínicas. Radiologia Geral. Curitiba. BR
  • Soboll, Danyel Scheidegger; Universidade Tecnológica Federal do Paraná. Departamento de Física. Curitiba. BR
Radiol. bras ; 42(5): 309-313, set.-out. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-530179
RESUMO

OBJETIVO:

O presente estudo consistiu em investigar a influência da radiação ionizante por raios X e raios gama sobre a estabilidade molecular de diversos meios de contraste radiológicos utilizados em exames de diagnóstico por imagem, por meio da espectroscopia de ressonância magnética nuclear de ÕH e 13C.

MATERIAIS E MÉTODOS:

Oito diferentes meios de contraste iodados (três iônicos e cinco não iônicos) foram expostos à radiação por raios X e raios gama. Em seguida, espectros de ressonância magnética nuclear de ÕH e 13C{ÕH} foram coletados.

RESULTADOS:

Os espectros de ressonância magnética nuclear de 13C{ÕH} de ambos os meios de contraste iônicos e não iônicos irradiados por raios X ou raios gama mostraram que não houve alterações na composição química desses contrastes.

CONCLUSÃO:

Não há problemas em armazenar as amostras nas salas, ou próximo aos equipamentos em que são realizados os exames. Enfatiza-se que a radiação recebida pelas amostras durante os ensaios foi direta, enquanto em uma sala de exames de radiodiagnóstico a radiação é indireta e, portanto, os níveis de radiações nestes casos são bastante inferiores àqueles empregados neste estudo.
ABSTRACT

OBJECTIVE:

The purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of ÕH and 13C nuclear magnetic resonance spectroscopy. MATERIALS AND

METHODS:

Eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the ÕH and 13C{ÕH} nuclear magnetic resonance spectra of these contrast media were collected.

RESULTS:

The ÕH and 13C{ÕH} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition.

CONCLUSION:

There is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Radiação Ionizante / Diagnóstico por Imagem / Espectroscopia de Ressonância Magnética / Meios de Contraste / Raios gama Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR / Universidade Tecnológica Federal do Paraná/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Radiação Ionizante / Diagnóstico por Imagem / Espectroscopia de Ressonância Magnética / Meios de Contraste / Raios gama Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Português Revista: Radiol. bras Assunto da revista: Diagnóstico por Imagem / Radiologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR / Universidade Tecnológica Federal do Paraná/BR