Optimización de un juego de reactivo para determinar fósforo por método ultravioleta / Determination of phosphorus presence by UV method and the of a reactant kit optimization
Rev. cuba. farm
;
43(2)mayo-ago. 2009. tab, graf
Artigo
em Espanhol
| LILACS
| ID: lil-531353
RESUMEN
Cada día, en la medicina clínica, cobra mayor auge el estudio de las enfermedades relacionadas con la formación del esqueleto y el metabolismo de los minerales, de gran importancia en afecciones renales y las relacionadas con la nutrición, donde desempe±a una función primordial el ion fósforo. Con vistas a ofertar a los laboratorios clínicos de Cuba un diagnosticador para determinar fósforo por un método ultravioleta, se formuló un monorreactivo listo para su uso, realizando la optimización de este, así como de la técnica de anßlisis dise±ada para su determinación, la cual es aplicable en los laboratorios clínicos de la red de salud que cuentan con el equipamiento tecnológico para la lectura en el espectro ultravioleta. Se optimizó cada uno de los componentes del monorreactivo, así como la técnica analítica mediante dise±os experimentales, y quedaron establecidos los valores óptimos de cada uno. Adicionalmente, se realizó una evaluación con el reactivo optimizado donde se obtuvo una curva lineal en el intervalo de interés clínico y un coeficiente de variación menor del 3 por ciento.
ABSTRACT
Every day, in clinical medicine, increase the interest for the diseases study related to skeletal development and the mineral metabolism, very important in renal affections and those related to nutrition, where it has an essential role the phosphorus ion. To offer Cuban clinical laboratories with diagnosis tool to determine the presence of phosphorus by a UV method, we formulated a monoreactive component ready for use, performing its optimization, as well as of the analysis technique designed to its assessment, which is applicable in clinical laboratories of health network with the technological equipment to read in UV spectrum. Each monoreactive component was optimized, as well as the analytical technique by means of experimental designs, staying the optimal values of each. Also, we performed an assessment using optimized reactive obtaining a lineal curve in clinical interest interval, and a variation coefficient lower than 3 percent.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Fósforo
/
Diagnóstico Clínico
/
Otimização de Processos
Tipo de estudo:
Estudo diagnóstico
Idioma:
Espanhol
Revista:
Rev. cuba. farm
Assunto da revista:
Farmácia
Ano de publicação:
2009
Tipo de documento:
Artigo
País de afiliação:
Cuba
Instituição/País de afiliação:
Empresa de Productos Biológicos Carlos J. Finlay/CU
Similares
MEDLINE
...
LILACS
LIS