Your browser doesn't support javascript.
loading
Métodos analíticos necesarios para el desarrollo de tabletas de metformina 500 mg / Analytical methods needed for Metformin 500mg tablets development
García Peña, Caridad M; León Rodríguez, Rafael; Martínez Espinosa, Vivian.
  • García Peña, Caridad M; Centro de Investigación y Desarrollo de Medicamentos. La Habana. CU
  • León Rodríguez, Rafael; Centro de Investigación y Desarrollo de Medicamentos. La Habana. CU
  • Martínez Espinosa, Vivian; Centro de Investigación y Desarrollo de Medicamentos. La Habana. CU
Rev. cuba. farm ; 43(3)sept.-dic. 2009.
Artigo em Espanhol | LILACS | ID: lil-531374
RESUMEN
El clorhidrato de metformina es un derivado de la biguanida usado en la diabetes mellitus no insulina dependiente, reduce la concentración de glucosa sanguínea sin incrementar la secreción de insulina, se considera un agente antihiperglucemiante y no un fármaco hipoglucemiante. El desarrollo tecnológico requiere de métodos analíticos confiables que permitan la cuantificación del fármaco en diferentes etapas de la investigación. El objetivo de este trabajo fue la validación del método analítico, reportado en la Farmacopea de los Estados Unidos (USP 31, 2008), por espectrofotometría ultravioleta y la adaptación del método analítico, reportado en la misma farmacopea, para el análisis de los compuestos relacionados en la determinación del principio activo en el producto terminado, por cromatografía líquida de alta resolución, validados para el control de la calidad y estudio de estabilidad de las tabletas de metformina 500 mg. A las técnicas validadas, por métodos cromatográficos y espectrofotométricos se le determinaron los parámetros de desempeño, especificidad, linealidad, exactitud y precisión. Las curvas de calibración para cada método, se realizaron en el intervalo de 60 al 140 por ciento, donde fueron lineales con coeficientes de correlación igual a 0,9994 y 0,99903, respectivamente; la prueba estadística para el intercepto y la pendiente se consideró no significativa. Se obtuvieron recobrados de 100,01 y 99,1 por ciento, respectivamente, en el intervalo de concentraciones estudiados y las pruebas de Cochran´(G) y Student´s (t) resultaron no significativas. Los coeficientes de variación en los estudios de la repetibilidad fueron iguales a 1,4 y 0,8 por ciento, respectivamente, para las 6 réplicas ensayadas, mientras que en los análisis de la precisión intermedia las pruebas de Fischer y Student fueron no significativas. Los resultados permiten concluir que ambos métodos cumplen con los requisitos establecidos como aceptables para cada uno de los casos...
ABSTRACT
Metformin hydrochloride is a biguanide-derivative used in non-dependent insulin diabetes mellitus reducing the blood glucose concentration without increases insulin secretion, and it is considered a anti-hyperglycemia agent and not a hypoglycemia one. Technological development requires of a reliable analytical methods allowing drug quantification in different stages of research. The aim of present paper was the analytical method validation, reported in USA Pharmacopeia (USP 31,2008) by UV-spectrophotometry and the adaptation of abovementioned method reported in the same pharmacopeia, for analysis of compound related in determination of active principle in end product, by high-performance liquid chromatography validated for quality control and study of Metformin (500-mg) tablets stability. In validated techniques by chromatographic spectrophtometric methods we determined performance parameter, specificity, linearity, accuracy, and precision. Calibration curves for each method was performed in intervals of 60to 140 percent, where they were linear with correlation coefficients equal to 0.9994 and 0.99903, respectively. Statistical test for interceptor and slope was considered as non-significant. We achieved recoveries of 100.01 and 99.1, respectively during interval of study concentrations, and the Cochran (G) and Student's (t) tests were not significant. Variation coefficients in studies of repetition were equal to 1.4 and 0.8, respectively for the 6 assayed replica, whereas in average precision analysis, Fischer and Student tests were not significant. Results allow concluding that both methods fulfill the established requirements as acceptable for each of cases during the concentration interval established.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Espectrofotometria Ultravioleta / Cromatografia Líquida de Alta Pressão / Estudos de Validação como Assunto / Metformina Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro de Investigación y Desarrollo de Medicamentos/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Espectrofotometria Ultravioleta / Cromatografia Líquida de Alta Pressão / Estudos de Validação como Assunto / Metformina Idioma: Espanhol Revista: Rev. cuba. farm Assunto da revista: Farmácia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro de Investigación y Desarrollo de Medicamentos/CU