Your browser doesn't support javascript.
loading
An in vitro comparison of nickel and chromium release from brackets
Haddad, Ana Cristina Soares Santos; Tortamano, Andre; Souza, Alexandre Luís de; Oliveira, Pedro Vitoriano de.
  • Haddad, Ana Cristina Soares Santos; University of São Paulo. School of Dentistry. Department of Orthodontics. São Paulo. BR
  • Tortamano, Andre; University of São Paulo. School of Dentistry. Department of Orthodontics. São Paulo. BR
  • Souza, Alexandre Luís de; University of São Paulo. Institute of Chemistry. Lab of Emission and Atomic Absorption Spectrometry. São Paulo. BR
  • Oliveira, Pedro Vitoriano de; University of São Paulo. Institute of Chemistry. Lab of Emission and Atomic Absorption Spectrometry. São Paulo. BR
Braz. oral res ; 23(4): 399-406, Oct.-Dec. 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-534211
ABSTRACT
This study aimed at comparing amounts of nickel (Ni) and chromium (Cr) released from brackets from different manufacturers in simulated oral environments. 280 brackets were equally divided into 7 groups according to manufacturer. 6 groups of brackets were stainless steel, and 1 group of brackets was made of a cobalt-chromium alloy with low Ni content (0.5 percent). International standard ISO 10271/2001 was applied to provide test methods. Each bracket was immersed in 0.5 ml of synthetic saliva (SS) or artificial plaque fluid (PF) over a period of 28 days at 37ºC. Solutions were replaced every 7 days, and were analyzed by spectrometry. The Kruskal-Wallis test was applied. Amounts of Ni release in SS (µg L-1 per week) varied between groups from "bellow detection limits" to 694, and from 49 to 5,948.5 in PF. The group of brackets made of cobalt-chromium alloy, with the least nickel content, did not release the least amounts of Ni. Amounts of Cr detected in SS and in PF (µg L-1 per week) were from 1 to 10.4 and from 50.5 to 8,225, respectively. It was therefore concluded that brackets from different manufacturers present different corrosion behavior. Further studies are necessary to determine clinical implications of the findings.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aço Inoxidável / Cromo / Ligas de Cromo / Braquetes Ortodônticos / Níquel Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aço Inoxidável / Cromo / Ligas de Cromo / Braquetes Ortodônticos / Níquel Idioma: Inglês Revista: Braz. oral res Assunto da revista: Odontologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: University of São Paulo/BR