Your browser doesn't support javascript.
loading
Avaliação da rugosidade superficial da resina composta filtek Z350 3M/ espe de baixa viscosidade exposta a enxaguatórios com e sem álcool / Assessment surface roughness of the flwable resin filtek Z350 3M/ espe exposed to mouthrinses with and without alcohol
Lucena, Maria Cecília Miranda de; Gomes, Renato Victor da Silva; Santos, Maria do Carmo Moreira da Silva.
  • Lucena, Maria Cecília Miranda de; Universidade Estadual de Pernambuco. Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Gomes, Renato Victor da Silva; Universidade Estadual de Pernambuco. Faculdade de Odontologia de Pernambuco. Camaragibe. BR
  • Santos, Maria do Carmo Moreira da Silva; Universidade de Pernambuco. Faculdade de Odontologia de Pernambuco. Recife. BR
Odontol. clín.-cient ; 9(1): 59-64, jan.-mar. 2010. tab, ilus, graf
Artigo em Português | LILACS, BBO | ID: lil-541609
RESUMO
O propósito deste trabalho foi o de verificar, in vitro, se existe alteração da rugosidade superficial provocada pela utilização de enxaguatórios com e sem álcool sobre a resina composta Filtek Z350 3M/ESPE de baixa viscosidade. A medida de rugosidade média RA foi obtida através da leitura em um rugosímetro. Foram utilizados 3 colutórios atualmente comercializados Listerine, Plax Classic e Plax Kids, além da água destilada e álcool etílico. Foram preparados 51 corpos de prova, divididos em 6 grupos água destilada, álcool etílico, listerine, plax classic e plax kids (com 10 amostras cada), e o grupo sem tratamento (composto de apenas 1 amostra). Os controles (negativo e positivo) foram realizados pela amostra sem tratamento e etanol, respectivamente. A lisura supertificial foi obtida com uma tira de poliéster, evitando qualquer influência do processo de polimento. As amostras ficaram imersas por um período total de 12 horas, o equivalente a 1 ano de utilização do enxaguatório. Foi possível observar um aumento significante da rugosidade em todos os grupos, com exceção do Plax Classic, quando comparada ao valor fixo obtido com a amostra sem ataque; entretanto, não houve diferença significante entre as soluções testadas.
ABSTRACT
The purpose of this study was to verify, in vitro, if there is a change of surface roughness caused by the use of mouthrinses with and without alcohol on the composite resin Filtek Z350 3M/ESPE flow. The measure of average roughness Ra was assessed by profilometry. Three mouthrinses currently marketed were used Listerine, Plax Classic and Plax Kids, in addition to distilled water and alcohol. Fifty one disc specimes were prepared, divided into six groups distilled water, ethyl alcohol, Listerine, Plax Classic and Plax Kids (with 10 specimens each), and the group without treatment (consisting of only 1 specimen). The negative and positive controls were carried out by the sample without treatment and ethanol, respectively. The surface smoothness was obtained with a polyester strip, avoiding any influence of the process of polishing. The specimens were immersed for a total period of 12 hours, equivalent to 1 year of use of mouthrinses. It was possible to see a significant increase of roughness in all groups, except the Plax Classic, as compared to the fixed value from the specimen without attack, but there was no significant difference between the solutions tested.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas / Antissépticos Bucais Idioma: Português Revista: Odontol. clín.-cient Assunto da revista: Odontologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Pernambuco/BR / Universidade de Pernambuco/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Resinas Compostas / Antissépticos Bucais Idioma: Português Revista: Odontol. clín.-cient Assunto da revista: Odontologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Pernambuco/BR / Universidade de Pernambuco/BR