Your browser doesn't support javascript.
loading
Utilização da espessura de dobras cutâneas para a estimativa da gordura corporal em idosos / Estimating body fat from skinfold thicknesses in the elderly
Rech, Cassiano Ricardo; Cordeiro, Braian Alves; Petroski, Edio Luiz; Vasconcelos, Francisco de Assis Guedes de.
  • Rech, Cassiano Ricardo; Universidade Estadual de Ponta Grossa. Programa Pós-Graduação em Educação Física. Ponta Grossa. BR
  • Cordeiro, Braian Alves; Universidade do Vale do Itajaí. Departamento de Nutrição. Itajaí. BR
  • Petroski, Edio Luiz; Universidade Federal de Santa Catarina. Programa de Pós-Graduação em Educação Física. Florianópolis. BR
  • Vasconcelos, Francisco de Assis Guedes de; Universidade Federal de Santa Catarina. Programa de Pós-Graduação em Nutrição. Florianópolis. BR
Rev. nutr ; 23(1): 17-26, jan.-fev. 2010. graf, tab
Artigo em Português | LILACS | ID: lil-547924
RESUMO

OBJETIVO:

Analisar a concordância de equações de espessura de dobras cutâneas para a estimativa da gordura corporal em idosos brasileiros, tendo como referência a Absortometria Radiológica de Dupla Energia.

MÉTODOS:

Trata-se de um estudo correlacional. Realizaram-se as medidas antropométricas (estatura, massa corporal, perímetros corporais e espessura de dobras cutâneas) de 180 idosos (60 homens e 120 mulheres) com idades entre 60 e 81 anos. A gordura corporal foi mensurada por meio da Absormetria Radiológica de Dupla Energia e comparada com os valores estimados pelas dobras cutâneas. Foram analisadas as equações de Durnin et al., Jackson etal., Visser et al. e Lean et al. Os critérios de validação cruzada sugeridos por Lohman e a análise gráfica das dispersões em relação à média, por meio do método proposto por Bland & Altman, foram utilizados.

RESULTADOS:

O grupo avaliado apresentou uma gordura corporal média de 23,1 por cento (DP=5,8 por cento) nos homens e 37,3 por cento (DP=6,9 por cento) nas mulheres, com uma variação entre 6 por cento a 51,4 por cento. Houve uma elevada concordância entre as equações generalizadas de Durnin et al. e a Absormetria Radiológica de Dupla Energia (64,4 por cento nos homens e 60,1 por cento nas mulheres). Nos homens as equações de dobras cutâneas tenderam a superestimar os valores de gordura corporal, já nas mulheres esses valores foram subestimados.

CONCLUSÃO:

As equações generalizadas desenvolvidas por Durnin et al. são válidas para a estimativa da gordura corporal em idosos do sul do Brasil.
ABSTRACT

OBJECTIVE:

The objective of this study was to analyze skinfold thickness equations for the estimation of body fat in terms of their concordance with dual energy X-ray absorptiometry results in elderly Brazilians.

METHODS:

This was a correlation study. Anthropometric measurements (height, body mass, body circumferences and skin fold thicknesses) of 180 elderly subjects (60 men and 120 women) aged 60 to 81 years were taken. Their body fat was measured with dual energy x-ray absorptiometry and compared with the values estimated from skinfold thickness measurements. Equations published by Durnin et al., Jackson et al., Visser et al. and Lean et al. were analyzed. The validation criteria described by Lohman were used together with the Bland and Altman method for graphical analysis of differences with relation to means.

RESULTS:

The men in the study group had a mean body fat of 23.1 percent (SD=5.8 percent) while the women had a mean body fat of 37.3 percent (SD=6.9 percent), with a 6 percent to 51.4 percent variation. The general equations published by Durnin et al. had great concordance with dual energy x-ray absorptiometry (64.4 percent for men and 60.1 percent for women). Skinfold thickness equations tended to overestimate men's body fat and underestimate women's body fat.

CONCLUSION:

The general equations proposed by Durnin et al. are a valid tool for estimating body fat in the elderly population of Southern Brazil.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Dobras Cutâneas / Idoso / Gordura Subcutânea Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. nutr Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Ponta Grossa/BR / Universidade Federal de Santa Catarina/BR / Universidade do Vale do Itajaí/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Dobras Cutâneas / Idoso / Gordura Subcutânea Limite: Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. nutr Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Ponta Grossa/BR / Universidade Federal de Santa Catarina/BR / Universidade do Vale do Itajaí/BR