Posicionamento ectópico de eletrodo de marcapasso / Ectopic positioning of pacemaker electrode
Mota, Gildo; Prazeres, Juliana; Freitas, Nelmacy; Magalhães, Luiz; Reis, Francisco; Aras, Roque.
  • Mota, Gildo; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
  • Prazeres, Juliana; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
  • Freitas, Nelmacy; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
  • Magalhães, Luiz; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
  • Reis, Francisco; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
  • Aras, Roque; Universidade Federal da Bahia. Hospital Universitário Professor Edgard Santos. Salvador. BR
Arq. bras. cardiol ; 94(5): e122-e124, maio 2010. ilus
Artigo em Inglês, Português | LILACS | ID: lil-548099
RESUMO
Apresentamos o caso de um paciente portador da forma cardíaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de síncope. Foi submetido a implante de marcapasso artificial definitivo dupla câmara. Após um ano do implante foi diagnosticado deslocamento de eletrodo atrial, sendo submetido a reimplante de eletrodo atrial. Após dois anos do primeiro procedimento cirúrgico, apresentava dispneia aos grandes esforços. Durante a avaliação, foi solicitado ecocardiograma, que detectou a presença de corpo estranho de características metálicas em câmaras cardíacas esquerdas, consistente com eletrodo de marcapasso ectópico.
ABSTRACT
The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Cardiomiopatia Chagásica / Migração de Corpo Estranho / Eletrodos Implantados Tipo de estudo: Estudo de etiologia Limite: Adulto / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal da Bahia/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Marca-Passo Artificial / Cardiomiopatia Chagásica / Migração de Corpo Estranho / Eletrodos Implantados Tipo de estudo: Estudo de etiologia Limite: Adulto / Humanos / Masculino Idioma: Inglês / Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal da Bahia/BR