Your browser doesn't support javascript.
loading
Valores da exoftalmometria média na população adulta da região do Grande ABC, São Paulo/Brasil / Normal exophthalmometric values in adult population of ABC Region, Sao Paulo/Brazil
Moysés, Nadia Ajub; Lucci, Lúcia Míriam Dumont; Fonseca Júnior, Nilson Lopes da; Rehder, José Ricardo Carvalho Lima.
  • Moysés, Nadia Ajub; Faculdade de Medicina do ABC. Disciplina de Oftalmologia. Setor de Cirurgia Plástica Ocular. Santo André. BR
  • Lucci, Lúcia Míriam Dumont; Faculdade de Medicina do ABC. Disciplina de Oftalmologia. Setor de Cirurgia Plástica Ocular. Santo André. BR
  • Fonseca Júnior, Nilson Lopes da; Faculdade de Medicina do ABC. Disciplina de Oftalmologia. Setor de Cirurgia Plástica Ocular. Santo André. BR
  • Rehder, José Ricardo Carvalho Lima; Faculdade de Medicina do ABC. Disciplina de Oftalmologia. Santo André. BR
Rev. bras. oftalmol ; 69(2): 104-109, Mar.-Apr. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-549906
RESUMO
OBJETIVO: Estabelecer padrões de normalidade dos valores da exoftalmometria de ambos os olhos e da distância entre os rebordos orbitários laterais (base) em adultos jovens da população do Grande ABC São Paulo/Brasil. MÉTODOS: Realizou-se a exoftalmometria com o exoftalmômetro de Hertel, em 129 pacientes do sexo feminino e 75 do sexo masculino, na faixa etária de 25 a 55 anos. Os pacientes foram separados em três grupos raciais (brancos, negros e pardos). RESULTADOS: A variação da exoftalmometria encontrada na população em estudo foi de 10 a 23mm, média de 15,57 ±2,43mm. No sexo feminino a média foi de 15,42 ±2,40mm e no masculino, 15,83 ±2,47mm. Não se encontrou uma relação estatisticamente significativa entre os sexos feminino e masculino (p=0,25). Na raça branca a média foi de 15,57 ±2,46mm, na negra foi de 16,20 ±2,70mm e na parda foi de 15,02 ±2,01mm. A diferença foi estatisticamente significativa (p=0,008) entre as raças negra e parda. A medida da base variou de 104 a 125mm (média de 113,91 ±4,37mm). A diferença entre homens e mulheres foi estatisticamente significativa (p<0,001). Na raça branca a média da base encontrada foi de 112,18 ±4,02mm, na negra foi de 115,37 ±4,71mm e na parda, 115,18 ±3,66mm. A diferença da média da base foi estatisticamente significativa (p<0,001) entre as raças branca e negra e branca e parda. Nenhum paciente apresentou assimetria entre os dois olhos maior que 2mm. CONCLUSÃO: O padrão de normalidade da exoftalmometria encontrado para a população em estudo foi de 10 a 23mm e a base variou de 104 a 125mm.
ABSTRACT
PURPOSE: To determine the normal exophthalmometry of both eyes and of the distance between lateral orbital rims (the base measurement) in young adults from ABC Region, São Paulo/Brazil. METHODS: Exophthalmometry, by Hertel's exophthalmometer, was made in 129 female and 75 male subjects, age ranging from 25 to 55 years. The subjects were divided in three groups of races (white, black and mulatto). RESULTS: The values of exophthalmometry ranged from 10 to 23mm, mean 15,57 ±2,43mm. In female the mean was 15,42 ±2,40mm and in male, 15,83 ±2,47mm. There is no statistically significant difference between female or male (p=0,25). In whites subjects the mean was 15,57 ±2,46mm, in black was 16,20 ±2,70mm and in mulatto was 15,02 ±2,01mm. There was a statistically significant difference between blaks and mulattos (p=0,008). The base measurement ranged from 104 to 125mm (mean 113,91 ±4,37mm). There was a statistically significant difference between males and females (p<0,001). In whites the base was 112,18 ±4,02mm, in blacks 115,37 ±4,71mm and in mulattos, 115,18 ±3,66mm. There was a statistically significant difference for the base measurement between white subjects and black ones, and between white subjects and mulattos (p<0,001). No individual had more than 2mm of assimetry between eyes. CONCLUSION: The normal exophthalmometric value in the studied population was 10 to 23mm and the base measurement ranged from 104 to 125mm.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Oftalmologia / Valores de Referência / Exoftalmia / Técnicas de Diagnóstico Oftalmológico Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina do ABC/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Oftalmologia / Valores de Referência / Exoftalmia / Técnicas de Diagnóstico Oftalmológico Limite: Adulto / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade de Medicina do ABC/BR