Objetivo:
Describir la morbilidad, pérdida sanguínea y tiempo quirúrgico en la realización de histerectomía vaginal con el uso de la pinza electroquirúrgica de coagulación bipolar plasmacinética.Metodología:
Se realizó un estudio retrospectivo en 18 pacientes sometidas a histerectomía vaginal por patología benigna uterina, utilizando energía plasmacinética durante el período de enero de 2007 a febrero de 2009, en el Hospital Central Norte de Petróleos Mexicanos.Resultados:
Tiempo quirúrgico de 59,4 +/- 19,3 min (rango 50-85 min), sangrado posoperatorio de 76,6 +/- 22,3 mi (rango 30-110 ml), peso del útero 497,3 +/- 88,9 g (rango 245-635 g) y tiempo de estancia intrahospitalaria de 2,1 +/- 0,6 días (rango 1-3 días). No se reportaron complicaciones durante el procedimiento ni en su recuperación posterior.Conclusiones:
El uso de la pinza electroquirúrgica de coagulación bipolar plasmacinética, es una alternativa efectiva y segura durante la histerectomía vaginal. Es necesaria la realización de un ensayo aleatorizado para compararla con la técnica tradicional para demostrar otros beneficios.ABSTRACT
Objective:
To describe morbility, blood loss and procedure time of vaginal hysterectomy using an electro-surgical bipolar vessel sealer.Methods:
Patients scheduled for vaginal hysterectomy using electrosurgical bipolar vessel sealer as the hemostasis technique during the period January 2007 to February 2009, at the Central Hospital North of Petróleos Mexicanos.Results:
A total of 18 patients underwent vaginal hysterectomy for some benign disease of the uterus. Among these patients, mean procedure time in the electrosurgical bipolar vessel sealer was 59.4 +/- 19.3 min (range 50-85 min). Mean estimated blood loss was 76.6 +/- 22.3 ml (range 30-110 ml), weight of the uterus was 497.3 +/- 88.9 g (range 245-635 g), and length of stay 2.1 +/- 0.6 days (range 1-3 days). There was no perioperative complication.Conclusion:
Electrosurgical bipolar vessel sealer is an effective alternative to sutures in vaginal hysterectomy. Larger adequately-powered studies are however still required.
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Eletrocoagulação
/
Histerectomia Vaginal
Tipo de estudo:
Estudo observacional
Limite:
Idoso
/
Aged80
/
Feminino
/
Humanos
Idioma:
Espanhol
Revista:
Rev. chil. obstet. ginecol
Assunto da revista:
Ginecologia
/
Obstetrícia
Ano de publicação:
2009
Tipo de documento:
Artigo
País de afiliação:
México
Instituição/País de afiliação:
Hospital Central Norte PEMEX/MX
Similares
MEDLINE
...
LILACS
LIS