Your browser doesn't support javascript.
loading
Atriosseptostomia por cateter balão guiada pela ecocardiografia em unidade de terapia intensiva neonatal / Balloon atrial septostomy guided by echocardiography in a neonatal intensive care unit
Lopes, Lilian M; Kawano, Christiane; Cristóvão, Salvador André Bavaresco; Nagamatsu, Célia Toshie; Fonseca, Luciana da; Furlanetto, Beatriz Helena Sanchez; Furlanetto, Gláucio; Silva, José Pedro da; Mangione, José Armando.
  • Lopes, Lilian M; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Kawano, Christiane; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Cristóvão, Salvador André Bavaresco; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Nagamatsu, Célia Toshie; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Fonseca, Luciana da; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Furlanetto, Beatriz Helena Sanchez; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Furlanetto, Gláucio; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Silva, José Pedro da; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
  • Mangione, José Armando; Hospital Beneficência Portuguesa de São Paulo. São Paulo. BR
Arq. bras. cardiol ; 95(2): 153-158, ago. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-557827
RESUMO
FUNDAMENTO A ecocardiografia bidimensional à beira do leito tem sido utilizada com sucesso para guiar a atriosseptostomia com cateter balão, agilizando o procedimento e evitando os riscos do transporte para o laboratório de hemodinâmica.

OBJETIVO:

Avaliar os resultados da atriosseptostomia com cateter balão à beira do leito em neonatos cianóticos.

MÉTODOS:

Entre jan/1997 e jul/2008, foram realizados 102 procedimentos de atriosseptostomia com cateter balão guiados pela ecocardiografia, sendo avaliados níveis de saturação, diâmetro da comunicação, saturação de oxigênio, resposta clínico-laboratorial e complicações relacionadas ao procedimento.

RESULTADOS:

De um total de 102 casos de Rashkind realizados à beira do leito, 98 preencheram os critérios de inclusão, sendo 90 neonatos do Grupo A (procedimento de Rashkind em fase pré-operatória) e 8 do Grupo B (procedimento em fase pós-operatória). Houve predomínio do sexo masculino (75 por cento), a idade média foi de 8,3 ± 9,3 dias, o peso médio foi de 3.100 ± 1.100 g e a transposição das grandes artérias foi a cardiopatia congênita mais frequente (n = 74). Comparando-se os valores das saturações pré e pós-procedimento (65,9 ± 19,5 por cento e 86 ± 9,7 por cento) e o diâmetro da comunicação interatrial pré e pós-procedimento (2,3 ± 1,0 mm e 5,5 ± 1,3 mm) houve diferença estatisticamente significativa (p < 0,001). Comparando-se os valores das saturações e o diâmetro da comunicação interatrial nos grupos de sobreviventes e não sobreviventes não houve diferença estatisticamente significativa (p > 0,05).

CONCLUSÃO:

A atriosseptostomia com cateter guiada pela ecocardiografia reduz os riscos por possibilitar a efetiva paliação sem perda de tempo em neonatos cianóticos, além de apresentar menores custos hospitalares.
ABSTRACT

BACKGROUND:

The bedside two-dimensional echocardiography (2-D ECHO) has been successfully used to guide the balloon atrial septostomy, speeding up the procedure and preventing the risks of transportation to the hemodynamics laboratory.

OBJECTIVE:

To assess the results of the bedside balloon atrial septostomy in cyanotic neonates.

METHODS:

Between January/1997 and July/2008, 102 atrioseptostomies by balloon catheter guided by echocardiography were carried out and saturation levels, defect diameter, oxygen saturation, clinical-laboratory response and complications related to the procedure were evaluated.

RESULTS:

Of 102 cases of bedside Rashkind septostomy, 98 met the inclusion criteria, with 90 neonates in Group A (Rashkind procedure in the preoperative phase) and 8 in Group B (procedure at the postoperative phase). There was a predominance of the male sex (75 percent), mean age was 8.3 ± 9.3 days and the mean weight was 3,100 ± 1,100 g; the transposition of the great arteries was the most frequent congenital heart disease (n = 74). When comparing the levels of saturation pre and post-procedure (65.9 ± 19.5 percent and 86 ± 9.7 percent) and the diameter of the interatrial septal defect pre and post-procedure (2.3 ± 1.0 mm and 5.5 ± 1.3 mm) there was a statistically significant difference (p < 0.001). When comparing the levels of saturation and the diameter of the interatrial septal defect between the group of survivors vs non-survivor, there was no statistically significant difference (p > 0.05).

CONCLUSION:

The balloon atrial septostomy guided by the echocardiography reduces the risks by allowing the effective palliative procedure to be carried out promptly in cyanotic neonates, in addition to presenting lower hospital costs.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transposição dos Grandes Vasos / Cateterismo / Ecocardiografia / Ultrassonografia de Intervenção / Comunicação Interatrial Limite: Feminino / Humanos / Lactente / Masculino / Recém-Nascido Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Beneficência Portuguesa de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Transposição dos Grandes Vasos / Cateterismo / Ecocardiografia / Ultrassonografia de Intervenção / Comunicação Interatrial Limite: Feminino / Humanos / Lactente / Masculino / Recém-Nascido Idioma: Português Revista: Arq. bras. cardiol Assunto da revista: Cardiologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Hospital Beneficência Portuguesa de São Paulo/BR