Técnicas de fisioterapia respiratória não provocam efeitos adversos na função pulmonar de crianças asmáticas hospitalizadas: ensaio clínico randomizado / Chest physiotherapy does not cause adverse effects on lung function in children hospitalized with asthma: randomized clinical trial
Lanza, Fernanda de Cordoba; Gazzotti, Mariana Rodrigues; Luque, Alexandre; Souza, Livian Aparecida; Nascimento, Roberta Zanardi Ruiz; Solé, Dirceu.
  • Lanza, Fernanda de Cordoba; Universidade Federal de São Paulo. Escola Paulista de Medicina. São Paulo. BR
  • Gazzotti, Mariana Rodrigues; Universidade Federal de São Paulo. Escola Paulista de Medicina. São Paulo. BR
  • Luque, Alexandre; Universidade de São Paulo. São Paulo. BR
  • Souza, Livian Aparecida; Universidade São Camilo. São Paulo. BR
  • Nascimento, Roberta Zanardi Ruiz; Universidade São Camilo. São Paulo. BR
  • Solé, Dirceu; Universidade Federal de São Paulo. Escola Paulista de Sâo Paulo. São Paulo. BR
Rev. bras. alergia imunopatol ; 33(2): 63-68, mar.-abr. 2010. ilus, tab
Artigo em Português | LILACS | ID: lil-565587
RESUMO
A asma é doença de prevalência elevada na criança e responsável por número significativo de hospitalizações. O emprego de técnicas convencionais de fisioterapia respiratória em pacientes durante exacerbação é controverso pela possibilidade de induzir ou acentuar broncoespasmo pré-existente.

Objetivos:

Identificar alterações na função pulmonar de pacientes asmáticos com hipersecreção brônquica e hospitalizados avaliando-se o volume expiratório forçado no primeiro segundo (VEF 1) e o pico de fluxo expiratório (PFE) após a realização de técnicas convencionais de fisioterapia respiratória.Pacientes e

métodos:

Ensaio clínico randomizado com 21 crianças asmáticas hospitalizadas por exacerbação e submetidas à tapotagem ou vibrocompressão. A função pulmonar e as frequências respiratória (FR) e cardíaca (FC) foram mensuradas antes, imediatamente após e 30 minutos após as terapias.

Resultados:

Onze pacientes foram submetidos à vibrocompres¬são (Vib) e dez a tapotagem (Tap). A idade variou entre 7 e 14 anos sendo 13 (62%) do sexo masculino. Os valores do VEF1 no grupo Tap antes, imediatamente após e após trinta minutos foram 1,47±0,20 L; 1,57±0,29 L; 1,46±0,37 L respectivamente (p=0,60) e 1,54 ± 0,31 L; 1,58±0,32 L; 1,65 ± 0,27 L (p=0,21) no grupo Vib. Não houve mudanças significantes nos valores de FR, FC e do PFE.

Conclusão:

a Vib e a Tap aplicadas à pacientes asmáticos hospita¬lizados por exacerbação não interferiram com a função pulmonar (VEF 1 e PFE) e não induziram desconforto respiratório nesses pacientes. As técnicas de tapotagem e vibrocompressão são seguras e podem ser realizadas nestes pacientes.
ABSTRACT
Asthma is a common disease in children, and it is one ofthe major causes of hospitalization due to exacerbations. The asthmatic patient can benefitfrom treatment with conventional chest physiotherapy techniques when there ís presence of bronchial secretions; however, it may improve bronchial constriction due to inflammation.

Objective:

To identify adverse effects on lung function in asthmatics with hyper secretion in the hospital for evaluation of forced expiratory volume in the first second (FEV1) and expiratory peak flow (PEF) after conventional chest physiotherapy techniques.

Method:

Randomized clinicai trlal with 21 children hospitalized for asthma exacerbation in a pediatric hospital, submitted to percussion and vibrocompression techniques. Lung function, respiratory rate (RR) and heart rate (HR) were measured before, immediately after and 30 minutes after each therapy

Results:

Eleven patients were included in the vibrocompression (Vib) group and ten in the percussion (Perc) group. The age ranged between 7 and 14 years, and 13 (62%) were male. Values of VEF1 in Perc before, immediately after, and thirty minutes after were 1.47±0.20 L, 1.57±0.29 L, 1.46±0.37 L respectively (p = 0.60) and 1.54 ± 0.31 L, 1.58±0.32 L, 1.65±0.27 L (p = 0.21) in Vib group. RR, HR and PEF did not change significantly

Conclusion:

Perc and Vib techniques did not alter lung function (FEV1 and PEF) and did not cause respiratory distress in hyperesecretory asthmatic patients during hospital admission, becoming safe techniques to be performed in this group.
Assuntos

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Infecções Respiratórias / Asma / Ensaios Clínicos Controlados Aleatórios como Assunto / Fluxo Expiratório Forçado / Modalidades de Fisioterapia / Técnicas e Procedimentos Diagnósticos Tipo de estudo: Ensaio Clínico Controlado / Estudo diagnóstico / Estudos de avaliação / Estudo de prevalência / Fatores de risco Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. alergia imunopatol Assunto da revista: Alergia e Imunologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade São Camilo/BR / Universidade de São Paulo/BR

Similares

MEDLINE

...
LILACS

LIS

Buscar no Google
Índice: LILACS (Américas) Assunto principal: Infecções Respiratórias / Asma / Ensaios Clínicos Controlados Aleatórios como Assunto / Fluxo Expiratório Forçado / Modalidades de Fisioterapia / Técnicas e Procedimentos Diagnósticos Tipo de estudo: Ensaio Clínico Controlado / Estudo diagnóstico / Estudos de avaliação / Estudo de prevalência / Fatores de risco Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. alergia imunopatol Assunto da revista: Alergia e Imunologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de São Paulo/BR / Universidade São Camilo/BR / Universidade de São Paulo/BR