Your browser doesn't support javascript.
loading
Selle marginal y asentamiento en dos sistemas cerámicos in-vitro / Marginal sealing and bonding in two ceramic systems in vitro
Andrade, Juliana; Ortega, Carlos Heverth; Aragón, Edgar Mauricio.
  • Andrade, Juliana; Universidad del Valle. Facultad de Salud. Escuela de Odontología. Santiago de Cali. CO
  • Ortega, Carlos Heverth; Universidad del Valle. Facultad de Salud. Escuela de Odontología. Santiago de Cali. CO
  • Aragón, Edgar Mauricio; Universidad del Valle. Facultad de Salud. Escuela de Odontología. Santiago de Cali. CO
Rev. Estomat ; 12(1): 66-82, mar. 2004. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-565766
RESUMEN
La rehabilitación oral en odontología demanda la búsqueda constante de nuevos materiales cada vez más biocompatibles y con apariencia más natural para satisfacer las necesidades actuales de los pacientes. El objetivo de esta investigación fue comparar, en un estudio cuasiexperimental in vitro, el nivel de asentamiento y selle marginal de cofias elaboradas según dos sistemas comerciales totalmente cerámicos, cuando fueron cementadas sobre dientes naturales. Para el estudio se utilizaron 30 dientes naturales extraídos por requerimientos ortodónticos en los cuales se realizaron sendas preparaciones dentarias estandarizadas para prótesis fija según las recomendaciones de ambos fabricantes y se tomaron impresiones estandarizadas en silicona. A partir de los modelos obtenidos mediante estas impresiones se fabricaron y se evaluaron las cofias de los sistemas libres de soporte metálico In Ceram® de la casa VITA y Empress 2® de la casa IVOCLAR simulando una situación clínica. En las 30 cofias obtenidas para los dientes naturales, se aplicaron dos medidas para evaluar el selle marginal y cinco medidas para determinar el grado de asentamiento por medio de la medición directa en el estereomicroscopio de luz, con el cual los resultados se obtuvieron en micras. El análisis de los datos se hizo mediante estadística descriptiva empleando la prueba estadística t de Student, comparando los promedios de los resultados entre los dos grupos experimentales, con una significancia estadística de p<0.05. Los promedios de las medidas de asentamiento se tomaron en los cortes en 5 puntos de referencia en ambos sistemas; en 3 delos 5 puntos los promedios fueron menores en el sistema Empress 2®, que sus correspondientes promedios por punto para el sistema In Ceram®.
ABSTRACT
Oral rehabilitation procedures constantly demand searching for more biocompatible materials with natural appearance to satisfy patient requirements. The objective of this investigation was to compare the accuracy level of fitness and marginal seal in vitro of abutments made of two commercial totally-ceramic systems on natural teeth. To obtain the pertinent data a quasi-experimental in vitro study was design; 30 natural teeth extracted by orthodontic requirements were experimentally prepared as abutments to receive and support prosthetic dental crowns prepared following the manufacturers’ recommendations. The reconstructive materials used and evaluated were the totally-ceramic systems In Ceram® (VITA) and Empress 2® (IVOCLAR). Each natural tooth was prepared in a standardized dental preparations for fixed prosthetics, and standardized silicone impressions were built simulating a clinical situation. Thirty abutments for the natural teeth were obtained, evaluating two measures of marginal sealing and five measures of adaptation by direct measuring from light stereomicroscopy in microns. For the data analysis, descriptive statistic was used by means of statistical test t of Student, by comparison between both experimental groups, with a statistical significance of p<0.05. The averages of adaptation levels measured for 5 reference points in cuts made in both systems, were smaller in 3 points for the system Empress 2 ® than those corresponding to in the In Ceram® system. For the marginal seal, the averages of the measures in 2 reference points were considered for both systems, resulting smaller in one point for the Empress 2® system, and equal for the other point. When the averages between both groups were compared, statistically significant differences were found in 3 of the 7 points used as reference. On the other four points there were no significant differences.
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estética Dentária Tipo de estudo: Guia de Prática Clínica Idioma: Espanhol Revista: Rev. Estomat Assunto da revista: Odontologia Ano de publicação: 2004 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad del Valle/CO

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Estética Dentária Tipo de estudo: Guia de Prática Clínica Idioma: Espanhol Revista: Rev. Estomat Assunto da revista: Odontologia Ano de publicação: 2004 Tipo de documento: Artigo País de afiliação: Colômbia Instituição/País de afiliação: Universidad del Valle/CO