Avalilação dos erros radiográficos cometidos por alunos de graduação durante o tratamento endodôntico / Evaluation of the radiographic errors performed by undergraduate students during endodontic treatment
Rev. odontol. Univ. Cid. Sao Paulo
;
22(3): 216-222, set.-dez. 2010. tab
Artigo
em Português
| LILACS, BBO
| ID: lil-574609
RESUMO
Introdução:
O objetivo deste estudo é avaliar os erros radiográficos cometidos por alunos de graduação durante as diferentes fases do tratamento endodôntico.Métodos:
Foram avaliadas 260 radiografias periapicais, divididas nos seguintes grupos radiografia inicial, radiografia para odontometria, radiografia da prova do cone principal de guta-percha, radiografia da condensação lateral e radiografia final. As radiografias foram realizadas com o mesmo tipo de película (E-Speed û Kodak) e aparelho de Raios X (50KV, 7,5mA), tempo de exposição de 0,8 segundos e processadas pelo método visual. Com auxílio de lupa e negatoscópio, três examinadores avaliaram as radiografias e registraram erros relacionados à técnica ou processamento.Resultados:
Os resultados mostraram que 57,70% das radiografias analisadas apresentaram algum tipo de erro (erro de técnica ou processamento). Não houve diferença estatística no número de radiografias com erros entre as diferentes fases do tratamento endodôntico.Conclusão:
A maior frequência de erros ocorreu no quesito processamento radiográfico (manchamento, presença de riscos e densidade inadequada da imagem).ABSTRACT
Introduction:
The aim of this study is to evaluate the radiographic errors performed by undergraduate studentsduring the endodontic treatment.Methods:
A total of 260 periapical radiographs were divided in these groups initial radiography, length tooth, try-in of gutta-percha point, corroborative of the lateral condensation e final radiography. The radiographs were obtained employing the same kind of film (E-speed, Kodak) and of X-Ray units (50KV, 7,5mA), with a 0,8-second exposure time, and they were processed by visual method. With help of a magnifying glass and a viewbox, three examiners analyzed the radiographs and registered errors related to technique and processing.Results:
The results showed that 57,70% of the radiographs analyzed exhibited some kind of errors (technique errors or processing). There were not significant differences in the number of the errors in the different phases of endodontic treatment.Conclusion:
The highest frequency of errors was seen in radiograph processing (stains, presence of splines and inadequate radiographic density).
Texto completo:
DisponíveL
Índice:
LILACS (Américas)
Assunto principal:
Controle de Qualidade
/
Radiografia Dentária
/
Guta-Percha
Limite:
Feminino
/
Humanos
/
Masculino
Idioma:
Português
Revista:
Rev. odontol. Univ. Cid. Sao Paulo
Assunto da revista:
Odontologia
Ano de publicação:
2010
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Faculdade de Odontologia de São José dos Campos/BR
Similares
MEDLINE
...
LILACS
LIS