RESUMEN
El reúso de los dializadores constituye un problema de gran magnitud en nuestro país. Se realizó un estudio observacional, descriptivo, prospectivo para determinar el Kuf de los dializadores de BF y AF reusados. Se estudiaron 8 pacientes en el Servicio de Hemodiálisis del Instituto de Nefrología Dr Abelardo Buch López, durante 18 sem, se utilizaron membranas de BF y AF, durante 2 etapas. El reúso fue automatizado, utilizando como germicida ácido peracético. Se midió Kuf in vitro e in vivo durante todas las hemodiálisis, se realizaron 432 hemodiálisis. El Kuf in vitro e in vivo de ambos tipos de dializadores disminuyó considerablemente en los primeros 6 usos. El Kuf de ambos tipos de dializadores tiene una importante disminución con el reprocesamiento.
ABSTRACT
Reuse of dialyzers is a serious problem in our country. To perform an observational, descriptive and prospective study to determine the Kuf of reused low-flow (LF) and high-flow (HF) dialyzers. Eight patients were studied in Hemodialysis Service of Dr Abelardo Buch López Nephrology Institute during 18 weeks, using LF and HL membranes in two stages. Reuse was automated using peracetic. acid like germicide. In vitro and in vivo Kuf was measured during all Hemodialysis (431 in total). In vitro and in vivo Kuf of both types of dialyzers decrease significantly during the first six uses. Kuf of both types of dialyzers has an important diminution with re-processing.